Change history for item: Gas Nova Florida VIRGO CTN 24 23.1 kW double-circuit

  1. Donny Darko 08 July 2023 12:30:20
    1. Create: Description #3472982
      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
    2. Create: Type of heating boiler #3472983
      Value: Gas, convection
    3. Create: Burner #3472984
      Value: Gas
    4. Create: Number of circuits #3472985
      Value: Double-circuit
    5. Create: Thermal power #3472986
      Value: 8.50 - 23.10 kW
    6. Create: Thermal load #3472987
      Value: 10 - 25.50 kW
    7. Create: The combustion chamber #3472988
      Value: Open
    8. Create: Efficiency #3472989
      Value: 90.6 %
    9. Create: Control #3472990
      Value: Electronic
    10. Create: Installation #3472991
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3472992
      Value: Copper
    12. Create: Mains voltage #3472993
      Value: Single-phase
    13. Create: Peculiarities #3472994
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3472995
      Value: 7 l
    15. Create: Equipment #3472996
      Value: Display
    16. Create: Fuel #3472997
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3472998
      Value: 2.7 cu. m/hour
    18. Create: LPG consumption #3472999
      Value: 2 kg/hour
    19. Create: Heat carrier temperature #3473000
      Value: 35 - 83 °С
    20. Create: Temperature in the DHW circuit #3473001
      Value: 35 - 57 °С
    21. Create: Hot water capacity at t 30°C #3473002
      Value: 11.2 l/min
    22. Create: Max. water pressure in the DHW circuit #3473003
      Value: 6 bar
    23. Create: Max. water pressure in the heating circuit #3473004
      Value: 3 bar
    24. Create: Gas connection #3473005
      Value: 3/4"
    25. Create: Heating circuit connection #3473006
      Value: 1/2"
    26. Create: Branch pipe for connecting the DHW circuit #3473007
      Value: 1/2"
    27. Create: Chimney diameter #3473008
      Value: 130 mm
    28. Create: Dimensions WxHxD #3473009
      Value: 420x750x315 mm
    29. Create: Weight #3473010
      Value: 302 kg
    30. Create: Additional Information #3473011
      Value: Touch control panel; management of two temperature zones; Possibility to control additional zones using expansion boards
    31. Create: Image #6335812
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8470225314729153632/orig
    32. Create: Preview image #6335813
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id8470225314729153632/orig
  2. Donny Darko 30 April 2023 08:42:04
    Name: Gas Nova Florida VIRGO CTN 24 23.1 kW double-circuit; Catalog: Heating boilers