Change history for item: Gas Nova Florida ORION CONDENSING KC 24 22.9 kW double-circuit

  1. Donny Darko 08 July 2023 12:28:50
    1. Create: Description #3472659
      Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3472660
      Value: Gas, condensing
    3. Create: Burner #3472661
      Value: Gas
    4. Create: Number of circuits #3472662
      Value: Double-circuit
    5. Create: Thermal power #3472663
      Value: 2.70 - 22.90 kW
    6. Create: Max. thermal load #3472664
      Value: 23.70 kW
    7. Create: The combustion chamber #3472665
      Value: Closed
    8. Create: Efficiency #3472666
      Value: 105.1 %
    9. Create: Control #3472667
      Value: Electronic
    10. Create: Installation #3472668
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3472669
      Value: Stainless steel
    12. Create: Mains voltage #3472670
      Value: Single-phase
    13. Create: Peculiarities #3472671
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    14. Create: Expansion tank volume #3472672
      Value: 10 l
    15. Create: Equipment #3472673
      Value: Display, room thermostat
    16. Create: Fuel #3472674
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3472675
      Value: 2.51 cu. m/hour
    18. Create: LPG consumption #3472676
      Value: 1.84 kg/hour
    19. Create: Nominal pressure of natural gas #3472677
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3472678
      Value: 37 mbar
    21. Create: Heat carrier temperature #3472679
      Value: 20 - 83 °C
    22. Create: Temperature in the DHW circuit #3472680
      Value: 35 - 62 °С
    23. Create: Hot water capacity at t 25°C #3472681
      Value: 16.1 l/min
    24. Create: Hot water capacity at t 30°C #3472682
      Value: 13.4 l/min
    25. Create: Hot water capacity at t 35°C #3472683
      Value: 11.5 l/min
    26. Create: Hot water capacity at t 40°C #3472684
      Value: 10 l/min
    27. Create: Hot water capacity at t 45°C #3472685
      Value: 8.9 l/min
    28. Create: Max. water pressure in the DHW circuit #3472686
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3472687
      Value: 3 bar
    30. Create: Gas connection #3472688
      Value: 1/2"
    31. Create: Heating circuit connection #3472689
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3472690
      Value: 1/2"
    33. Create: Coaxial chimney diameter #3472691
      Value: 60/100 mm
    34. Create: Connection of a separate chimney diameter 80 mm #3472692
      Value: Yes
    35. Create: Dimensions WxHxD #3472693
      Value: 420x750x315 mm
    36. Create: Weight #3472694
      Value: 305 kg
    37. Create: Additional Information #3472695
      Value: Touchscreen; Possibility to install expansion boards for controlling low-temperature heating zones
    38. Create: Image #6335792
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3101450562887276654/orig
    39. Create: Preview image #6335793
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3101450562887276654/orig
  2. Donny Darko 30 April 2023 08:42:00
    Name: Gas Nova Florida ORION CONDENSING KC 24 22.9 kW double-circuit; Catalog: Heating boilers