Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:28:50
Create:
Description #3472659
Value: Type of heating boiler: gas, max. heating power: 22.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
Create:
Type of heating boiler #3472660
Value: Gas, condensing
Create:
Burner #3472661
Value: Gas
Create:
Number of circuits #3472662
Value: Double-circuit
Create:
Thermal power #3472663
Value: 2.70 - 22.90 kW
Create:
Max. thermal load #3472664
Value: 23.70 kW
Create:
The combustion chamber #3472665
Value: Closed
Create:
Efficiency #3472666
Value: 105.1 %
Create:
Control #3472667
Value: Electronic
Create:
Installation #3472668
Value: Wall-mounted
Create:
Primary heat exchanger material #3472669
Value: Stainless steel
Create:
Mains voltage #3472670
Value: Single-phase
Create:
Peculiarities #3472671
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3472672
Value: 10 l
Create:
Equipment #3472673
Value: Display, room thermostat
Create:
Fuel #3472674
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3472675
Value: 2.51 cu. m/hour
Create:
LPG consumption #3472676
Value: 1.84 kg/hour
Create:
Nominal pressure of natural gas #3472677
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3472678
Value: 37 mbar
Create:
Heat carrier temperature #3472679
Value: 20 - 83 °C
Create:
Temperature in the DHW circuit #3472680
Value: 35 - 62 °С
Create:
Hot water capacity at t 25°C #3472681
Value: 16.1 l/min
Create:
Hot water capacity at t 30°C #3472682
Value: 13.4 l/min
Create:
Hot water capacity at t 35°C #3472683
Value: 11.5 l/min
Create:
Hot water capacity at t 40°C #3472684
Value: 10 l/min
Create:
Hot water capacity at t 45°C #3472685
Value: 8.9 l/min
Create:
Max. water pressure in the DHW circuit #3472686
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3472687
Value: 3 bar
Create:
Gas connection #3472688
Value: 1/2"
Create:
Heating circuit connection #3472689
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3472690
Value: 1/2"
Create:
Coaxial chimney diameter #3472691
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3472692
Value: Yes
Create:
Dimensions WxHxD #3472693
Value: 420x750x315 mm
Create:
Weight #3472694
Value: 305 kg
Create:
Additional Information #3472695
Value: Touchscreen; Possibility to install expansion boards for controlling low-temperature heating zones
Create:
Image #6335792
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3101450562887276654/orig
Create:
Preview image #6335793
URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3101450562887276654/orig
Donny Darko 30 April 2023 08:42:00
Name: Gas Nova Florida ORION CONDENSING KC 24 22.9 kW double-circuit; Catalog: Heating boilers