Change history for item: Gas Nova Florida PICTOR CONDENSING LINE TECH KC 32 30.6 kW dual circuit

  1. Donny Darko 08 July 2023 12:28:27
    1. Create: Description #3472497
      Value: Type of heating boiler: gas, max. heating power: 30.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3472498
      Value: Gas, condensing
    3. Create: Burner #3472499
      Value: Gas
    4. Create: Number of circuits #3472500
      Value: Double-circuit
    5. Create: Thermal power #3472501
      Value: 8.70 - 30.60 kW
    6. Create: Max. thermal load #3472502
      Value: 31.40 kW
    7. Create: The combustion chamber #3472503
      Value: Closed
    8. Create: Efficiency #3472504
      Value: 105.4 %
    9. Create: Control #3472505
      Value: Electronic
    10. Create: Installation #3472506
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3472507
      Value: Stainless steel
    12. Create: Mains voltage #3472508
      Value: Single-phase
    13. Create: Peculiarities #3472509
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, connector for external control, thermometer
    14. Create: Expansion tank volume #3472510
      Value: 10 l
    15. Create: Equipment #3472511
      Value: Display
    16. Create: Fuel #3472512
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3472513
      Value: 3.32 cu. m/hour
    18. Create: LPG consumption #3472514
      Value: 2.47 kg/hour
    19. Create: Nominal pressure of natural gas #3472515
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3472516
      Value: 37 mbar
    21. Create: Heat carrier temperature #3472517
      Value: 20 - 78 °С
    22. Create: Max. temperature in the DHW circuit #3472518
      Value: 62 °С
    23. Create: Hot water capacity at t 30°C #3472519
      Value: 16.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3472520
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3472521
      Value: 3 bar
    26. Create: Gas connection #3472522
      Value: 1/2"
    27. Create: Heating circuit connection #3472523
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3472524
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3472525
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3472526
      Value: Yes
    31. Create: Dimensions WxHxD #3472527
      Value: 450x750x325mm
    32. Create: Weight #3472528
      Value: 394 kg
    33. Create: Image #6335780
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
    34. Create: Preview image #6335781
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
  2. Donny Darko 30 April 2023 08:41:58
    Name: Gas Nova Florida PICTOR CONDENSING LINE TECH KC 32 30.6 kW dual circuit; Catalog: Heating boilers