Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:28:20
Create:
Description #3472434
Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3472435
Value: Gas, condensing
Create:
Burner #3472436
Value: Gas
Create:
Number of circuits #3472437
Value: Double-circuit
Create:
Thermal power #3472438
Value: 6.50 - 23.10 kW
Create:
Max. thermal load #3472439
Value: 23.70 kW
Create:
The combustion chamber #3472440
Value: Closed
Create:
Efficiency #3472441
Value: 104.8 %
Create:
Control #3472442
Value: Electronic
Create:
Installation #3472443
Value: Wall-mounted
Create:
Primary heat exchanger material #3472444
Value: Stainless steel
Create:
Mains voltage #3472445
Value: Single-phase
Create:
Peculiarities #3472446
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, connector for external control, thermometer
Create:
Expansion tank volume #3472447
Value: 10 l
Create:
Equipment #3472448
Value: Display
Create:
Fuel #3472449
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3472450
Value: 2.51 cu. m/hour
Create:
LPG consumption #3472451
Value: 1.83 kg/h
Create:
Nominal pressure of natural gas #3472452
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3472453
Value: 37 mbar
Create:
Heat carrier temperature #3472454
Value: 20 - 78 °С
Create:
Max. temperature in the DHW circuit #3472455
Value: 62 °С
Create:
Hot water capacity at t 30°C #3472456
Value: 13.5 l/min
Create:
Max. water pressure in the DHW circuit #3472457
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3472458
Value: 3 bar
Create:
Gas connection #3472459
Value: 1/2"
Create:
Heating circuit connection #3472460
Value: 3/4"
Create:
Coaxial chimney diameter #3472461
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3472462
Value: Yes
Create:
Dimensions WxHxD #3472463
Value: 450x750x325mm
Create:
Weight #3472464
Value: 36.6 kg
Create:
Additional Information #3472465
Value: Possibility to control an external boiler
Create:
Image #6335776
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
Create:
Preview image #6335777
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
Donny Darko 30 April 2023 08:41:58
Name: Gas Nova Florida PICTOR CONDENSING LINE TECH KC 24 23.1 kW dual circuit; Catalog: Heating boilers