Change history for item: Gas Nova Florida PICTOR CONDENSING LINE TECH KC 24 23.1 kW dual circuit

  1. Donny Darko 08 July 2023 12:28:20
    1. Create: Description #3472434
      Value: Type of heating boiler: gas, max. heating power: 23.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3472435
      Value: Gas, condensing
    3. Create: Burner #3472436
      Value: Gas
    4. Create: Number of circuits #3472437
      Value: Double-circuit
    5. Create: Thermal power #3472438
      Value: 6.50 - 23.10 kW
    6. Create: Max. thermal load #3472439
      Value: 23.70 kW
    7. Create: The combustion chamber #3472440
      Value: Closed
    8. Create: Efficiency #3472441
      Value: 104.8 %
    9. Create: Control #3472442
      Value: Electronic
    10. Create: Installation #3472443
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3472444
      Value: Stainless steel
    12. Create: Mains voltage #3472445
      Value: Single-phase
    13. Create: Peculiarities #3472446
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, connector for external control, thermometer
    14. Create: Expansion tank volume #3472447
      Value: 10 l
    15. Create: Equipment #3472448
      Value: Display
    16. Create: Fuel #3472449
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3472450
      Value: 2.51 cu. m/hour
    18. Create: LPG consumption #3472451
      Value: 1.83 kg/h
    19. Create: Nominal pressure of natural gas #3472452
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3472453
      Value: 37 mbar
    21. Create: Heat carrier temperature #3472454
      Value: 20 - 78 °С
    22. Create: Max. temperature in the DHW circuit #3472455
      Value: 62 °С
    23. Create: Hot water capacity at t 30°C #3472456
      Value: 13.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3472457
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3472458
      Value: 3 bar
    26. Create: Gas connection #3472459
      Value: 1/2"
    27. Create: Heating circuit connection #3472460
      Value: 3/4"
    28. Create: Coaxial chimney diameter #3472461
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3472462
      Value: Yes
    30. Create: Dimensions WxHxD #3472463
      Value: 450x750x325mm
    31. Create: Weight #3472464
      Value: 36.6 kg
    32. Create: Additional Information #3472465
      Value: Possibility to control an external boiler
    33. Create: Image #6335776
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
    34. Create: Preview image #6335777
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1822108382968813111/orig
  2. Donny Darko 30 April 2023 08:41:58
    Name: Gas Nova Florida PICTOR CONDENSING LINE TECH KC 24 23.1 kW dual circuit; Catalog: Heating boilers