Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:27:54
Create:
Description #3472218
Value: Type of heating boiler: gas, max. heating power: 28.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3472219
Value: Gas, convection
Create:
Burner #3472220
Value: Gas
Create:
Number of circuits #3472221
Value: Double-circuit
Create:
Thermal power #3472222
Value: 12 - 28.60 kW
Create:
Max. thermal load #3472223
Value: 30.50 kW
Create:
The combustion chamber #3472224
Value: Closed
Create:
Efficiency #3472225
Value: 93.7 %
Create:
Control #3472226
Value: Electronic
Create:
Installation #3472227
Value: Wall-mounted
Create:
Primary heat exchanger material #3472228
Value: Copper
Create:
Secondary heat exchanger material #3472229
Value: Stainless steel
Create:
Mains voltage #3472230
Value: Single-phase
Create:
Peculiarities #3472231
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3472232
Value: 10 l
Create:
Equipment #3472233
Value: Display, room thermostat
Create:
Fuel #3472234
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3472235
Value: 3.23 cu. m/hour
Create:
LPG consumption #3472236
Value: 2.37 kg/h
Create:
Nominal pressure of natural gas #3472237
Value: 13 - 20 mbar
Create:
Heat carrier temperature #3472238
Value: 35 - 78 °С
Create:
Temperature in the DHW circuit #3472239
Value: 35 - 57 °С
Create:
Hot water capacity at t 25°C #3472240
Value: 17 l/min
Create:
Hot water capacity at t 30°C #3472241
Value: 14.2 l/min
Create:
Hot water capacity at t 35°C #3472242
Value: 12.2 l/min
Create:
Hot water capacity at t 40°C #3472243
Value: 10.7 l/min
Create:
Hot water capacity at t 45°C #3472244
Value: 9.4 l/min
Create:
Max. water pressure in the DHW circuit #3472245
Value: 6 bar
Create:
Max. water pressure in the heating circuit #3472246
Value: 3 bar
Create:
Gas connection #3472247
Value: 1/2"
Create:
Heating circuit connection #3472248
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3472249
Value: 1/2"
Create:
Coaxial chimney diameter #3472250
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3472251
Value: Yes
Create:
Dimensions WxHxD #3472252
Value: 420x750x315 mm
Create:
Weight #3472253
Value: 39.5 kg
Create:
Additional Information #3472254
Value: Touch control panel
Create:
Image #6335762
URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id1013199828180316187/orig
Create:
Preview image #6335763
URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id1013199828180316187/orig
Donny Darko 30 April 2023 08:41:55
Name: Gas Nova Florida ORION CTFS 28 28.6 kW double-circuit; Catalog: Heating boilers