Change history for item: Gas Nova Florida ORION CTFS 24 23.7 kW double-circuit

  1. Donny Darko 08 July 2023 12:27:35
    1. Create: Description #3472180
      Value: Type of heating boiler: gas, max. heating power: 23.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of supply: single-phase,
    2. Create: Type of heating boiler #3472181
      Value: Gas, convection
    3. Create: Burner #3472182
      Value: Gas
    4. Create: Number of circuits #3472183
      Value: Double-circuit
    5. Create: Thermal power #3472184
      Value: 11.10 - 23.70 kW
    6. Create: Max. thermal load #3472185
      Value: 25.50 kW
    7. Create: The combustion chamber #3472186
      Value: Closed
    8. Create: Efficiency #3472187
      Value: 93 %
    9. Create: Control #3472188
      Value: Electronic
    10. Create: Installation #3472189
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3472190
      Value: Copper
    12. Create: Secondary heat exchanger material #3472191
      Value: Stainless steel
    13. Create: Mains voltage #3472192
      Value: Single-phase
    14. Create: Peculiarities #3472193
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3472194
      Value: 10 l
    16. Create: Equipment #3472195
      Value: Display
    17. Create: Fuel #3472196
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3472197
      Value: 2.7 cu. m/hour
    19. Create: LPG consumption #3472198
      Value: 1.98 kg/hour
    20. Create: Nominal pressure of natural gas #3472199
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3472200
      Value: 37 mbar
    22. Create: Heat carrier temperature #3472201
      Value: 35 - 78 °С
    23. Create: Temperature in the DHW circuit #3472202
      Value: 35 - 57 °С
    24. Create: Hot water capacity at t 25°C #3472203
      Value: 13.9 l/min
    25. Create: Hot water capacity at t 30°C #3472204
      Value: 11.6 l/min
    26. Create: Hot water capacity at t 35°C #3472205
      Value: 9.9 l/min
    27. Create: Hot water capacity at t 40°C #3472206
      Value: 8.7 l/min
    28. Create: Hot water capacity at t 45°C #3472207
      Value: 7.7 l/min
    29. Create: Max. water pressure in the DHW circuit #3472208
      Value: 6 bar
    30. Create: Max. water pressure in the heating circuit #3472209
      Value: 3 bar
    31. Create: Gas connection #3472210
      Value: 1/2"
    32. Create: Heating circuit connection #3472211
      Value: 3/4"
    33. Create: Branch pipe for connecting the DHW circuit #3472212
      Value: 1/2"
    34. Create: Coaxial chimney diameter #3472213
      Value: 60/100 mm
    35. Create: Connection of a separate chimney diameter 80 mm #3472214
      Value: Yes
    36. Create: Dimensions WxHxD #3472215
      Value: 420x750x315 mm
    37. Create: Weight #3472216
      Value: 28 kg
    38. Create: Additional Information #3472217
      Value: Touch control panel
    39. Create: Image #6335760
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id1013199828180316187/orig
    40. Create: Preview image #6335761
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id1013199828180316187/orig
  2. Donny Darko 30 April 2023 08:41:54
    Name: Gas Nova Florida ORION CTFS 24 23.7 kW double-circuit; Catalog: Heating boilers