Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:27:26
Create:
Description #3472104
Value: Type of heating boiler: gas, max. heating power: 22.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
Create:
Type of heating boiler #3472105
Value: Gas, condensing
Create:
Burner #3472106
Value: Gas
Create:
Number of circuits #3472107
Value: Double-circuit
Create:
Thermal power #3472108
Value: 6.50 - 22.70 kW
Create:
Max. thermal load #3472109
Value: 23.10 kW
Create:
The combustion chamber #3472110
Value: Closed
Create:
Efficiency #3472111
Value: 104.8 %
Create:
Control #3472112
Value: Electronic
Create:
Installation #3472113
Value: Wall-mounted
Create:
Primary heat exchanger material #3472114
Value: Stainless steel
Create:
Secondary heat exchanger material #3472115
Value: Stainless steel
Create:
Mains voltage #3472116
Value: Single-phase
Create:
Peculiarities #3472117
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
The volume of the built-in boiler #3472118
Value: 25 l
Create:
Expansion tank volume #3472119
Value: 10 l
Create:
Equipment #3472120
Value: Built-in boiler, display
Create:
Fuel #3472121
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3472122
Value: 2.51 cu. m/hour
Create:
LPG consumption #3472123
Value: 1.84 kg/hour
Create:
Nominal pressure of natural gas #3472124
Value: 13 mbar
Create:
Permissible LPG pressure #3472125
Value: 37 mbar
Create:
Heat carrier temperature #3472126
Value: 20 - 83 °C
Create:
Temperature in the DHW circuit #3472127
Value: 35 - 62 °С
Create:
Hot water capacity at t 25°C #3472128
Value: 16.1 l/min
Create:
Hot water capacity at t 30°C #3472129
Value: 13.4 l/min
Create:
Hot water capacity at t 35°C #3472130
Value: 11.5 l/min
Create:
Hot water capacity at t 40°C #3472131
Value: 10 l/min
Create:
Hot water capacity at t 45°C #3472132
Value: 8.9 l/min
Create:
Max. water pressure in the DHW circuit #3472133
Value: 8 bar
Create:
Max. water pressure in the heating circuit #3472134
Value: 3 bar
Create:
Gas connection #3472135
Value: 1/2"
Create:
Heating circuit connection #3472136
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3472137
Value: 1/2"
Create:
Coaxial chimney diameter #3472138
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3472139
Value: Yes
Create:
Dimensions WxHxD #3472140
Value: 450x750x535 mm
Create:
Weight #3472141
Value: 68.4 kg
Create:
Image #6335756
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id2942932686452616998.jpeg/orig
Create:
Preview image #6335757
URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id2942932686452616998.jpeg/orig
Donny Darko 30 April 2023 08:41:54
Name: Gas Nova Florida LIBRA CONDENSING LINE TECH KB 24 22.7 kW double-circuit; Catalog: Heating boilers