Change history for item: Gas Nova Florida PICTOR DUAL CTN 24 23.3 kW double-circuit

  1. Donny Darko 08 July 2023 12:25:21
    1. Create: Description #3471550
      Value: Type of heating boiler: gas, max. heating power: 23.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3471551
      Value: Gas, convection
    3. Create: Burner #3471552
      Value: Gas
    4. Create: Number of circuits #3471553
      Value: Double-circuit
    5. Create: Thermal power #3471554
      Value: 9.90 - 23.30 kW
    6. Create: Thermal load #3471555
      Value: 11 - 25.70 kW
    7. Create: The combustion chamber #3471556
      Value: Open
    8. Create: Efficiency #3471557
      Value: 90.7 %
    9. Create: Control #3471558
      Value: Electronic
    10. Create: Installation #3471559
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3471560
      Value: Copper
    12. Create: Secondary heat exchanger material #3471561
      Value: Stainless steel
    13. Create: Mains voltage #3471562
      Value: Single-phase
    14. Create: Peculiarities #3471563
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    15. Create: Expansion tank volume #3471564
      Value: 8 l
    16. Create: Fuel #3471565
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3471566
      Value: 2.72 cu. m/hour
    18. Create: LPG consumption #3471567
      Value: 2.02 kg/hour
    19. Create: Nominal pressure of natural gas #3471568
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3471569
      Value: 37 mbar
    21. Create: Heat carrier temperature #3471570
      Value: 26 - 85 °С
    22. Create: Max. temperature in the DHW circuit #3471571
      Value: 62 °С
    23. Create: Hot water capacity at t 25°C #3471572
      Value: 13.4 l/min
    24. Create: Hot water capacity at t 30°C #3471573
      Value: 11.1 l/min
    25. Create: Hot water capacity at t 35°C #3471574
      Value: 9.6 l/min
    26. Create: Hot water capacity at t 40°C #3471575
      Value: 8.4 l/min
    27. Create: Hot water capacity at t 45°C #3471576
      Value: 7.4 l/min
    28. Create: Max. water pressure in the DHW circuit #3471577
      Value: 8 bar
    29. Create: Max. water pressure in the heating circuit #3471578
      Value: 3 bar
    30. Create: Gas connection #3471579
      Value: 1/2"
    31. Create: Heating circuit connection #3471580
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3471581
      Value: 1/2"
    33. Create: Chimney diameter #3471582
      Value: 130 mm
    34. Create: Dimensions WxHxD #3471583
      Value: 450x750x325mm
    35. Create: Weight #3471584
      Value: 36.5 kg
    36. Create: Image #6335720
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id9014539389287790624/orig
    37. Create: Preview image #6335721
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id9014539389287790624/orig
  2. Donny Darko 30 April 2023 08:41:49
    Name: Gas Nova Florida PICTOR DUAL CTN 24 23.3 kW double-circuit; Catalog: Heating boilers