Change history for item: Wall-mounted double-circuit NEVALUX 8214M kW Natural gas

  1. Donny Darko 08 July 2023 12:22:41
    1. Create: Width #33195
      Value: 370
    2. Create: Height #33196
      Value: 670
    3. Create: Description #3470935
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    4. Create: Type of heating boiler #3470936
      Value: Gas
    5. Create: Number of circuits #3470937
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3470938
      Value: Convection
    7. Create: Combustion chamber type #3470939
      Value: Closed
    8. Create: Primary heat exchanger material #3470940
      Value: Copper
    9. Create: Accommodation #3470941
      Value: Wall
    10. Create: Power type #3470942
      Value: Single-phase
    11. Create: Control #3470943
      Value: Electronic
    12. Create: Equipment #3470944
      Value: Built-in exhaust fan, display
    13. Create: Functions #3470945
      Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, switch-on indication, flame modulation
    14. Create: Minimum heat output #3470946
      Value: 16 kW
    15. Create: Max. thermal power #3470947
      Value: 18 kW
    16. Create: Efficiency #3470948
      Value: 91 %
    17. Create: Heated area #3470949
      Value: 180 m²
    18. Create: Maximum water pressure in the heating circuit #3470950
      Value: 3 bar
    19. Create: Minimum heating medium temperature #3470951
      Value: 30°C
    20. Create: Maximum coolant temperature #3470952
      Value: 80°C
    21. Create: Expansion tank volume #3470953
      Value: 6 l
    22. Create: Gas connection #3470954
      Value: 3/4"
    23. Create: Heating circuit connection #3470955
      Value: 3/4"
    24. Create: Branch pipe for connecting the DHW circuit #3470956
      Value: 1/2"
    25. Create: Coaxial chimney diameter #3470957
      Value: 60/100 mm
    26. Create: Burner #3470958
      Value: Gas
    27. Create: Secondary heat exchanger material #3470959
      Value: Stainless steel
    28. Create: Minimum temperature in the DHW circuit #3470960
      Value: 15°C
    29. Create: Maximum temperature in the DHW circuit #3470961
      Value: 80°C
    30. Create: Maximum water pressure in the DHW circuit #3470962
      Value: 10 bar
    31. Create: Fuel #3470963
      Value: Natural gas
    32. Create: Hot water capacity at t 25°C #3470964
      Value: 13.5 l/min
    33. Create: Nominal pressure of natural gas #3470965
      Value: 20 mbar
    34. Create: Natural gas consumption #3470966
      Value: 1.4 m³/hour
    35. Create: LPG consumption #3470967
      Value: 3.1 kg/h
    36. Create: Depth #3470968
      Value: 250 mm
    37. Create: Weight #3470969
      Value: 27 kg
    38. Create: Image #6335669
      URL: https://avatars.mds.yandex.net/get-mpic/5232557/img_id2576823294228825614.jpeg/orig
    39. Create: Image #6335670
      URL: https://avatars.mds.yandex.net/get-mpic/1657306/img_id1985053000169235525.jpeg/orig
    40. Create: Image #6335671
      URL: https://avatars.mds.yandex.net/get-mpic/7547708/img_id9120049537983845445.png/orig
    41. Create: Image #6335672
      URL: https://avatars.mds.yandex.net/get-mpic/4033296/img_id7707881523215241026.jpeg/orig
    42. Create: Preview image #6335673
      URL: https://avatars.mds.yandex.net/get-mpic/5232557/img_id2576823294228825614.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:41
    Name: Wall-mounted double-circuit NEVALUX 8214M kW Natural gas; Catalog: Heating boilers