Change history for item: Neva Lux 7211

  1. Donny Darko 08 July 2023 12:22:26
    1. Create: Description #3470821
      Value: Type of heating boiler: gas, max. thermal power: 11 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3470822
      Value: Gas, convection
    3. Create: Burner #3470823
      Value: Gas
    4. Create: Number of circuits #3470824
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Max. thermal power #3470825
      Value: 11 kW
    6. Create: Max. thermal load #3470826
      Value: 12.70 kW
    7. Create: The combustion chamber #3470827
      Value: Closed
    8. Create: Heated area #3470828
      Value: 110 sq.m
    9. Create: Efficiency #3470829
      Value: 92.5 %
    10. Create: Control #3470830
      Value: Electronic
    11. Create: Installation #3470831
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3470832
      Value: Copper
    13. Create: Mains voltage #3470833
      Value: Single-phase
    14. Create: Peculiarities #3470834
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    15. Create: Expansion tank volume #3470835
      Value: 6 l
    16. Create: Equipment #3470836
      Value: Display
    17. Create: Fuel #3470837
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3470838
      Value: 1.3 cu. m/hour
    19. Create: LPG consumption #3470839
      Value: 1 kg/hour
    20. Create: Nominal pressure of natural gas #3470840
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3470841
      Value: 29 mbar
    22. Create: Heat carrier temperature #3470842
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3470843
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 25°C #3470844
      Value: 9 l/min
    25. Create: Max. water pressure in the DHW circuit #3470845
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3470846
      Value: 3 bar
    27. Create: Gas connection #3470847
      Value: 3/4"
    28. Create: Heating circuit connection #3470848
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3470849
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3470850
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3470851
      Value: Yes
    32. Create: Dimensions WxHxD #3470852
      Value: 380x680x250mm
    33. Create: Additional Information #3470853
      Value: Turbocharged
    34. Create: Image #6335653
      URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3811597316087843613.jpeg/orig
    35. Create: Image #6335654
      URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id1093441972428101517.jpeg/orig
    36. Create: Image #6335655
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id7251591260513451069.png/orig
    37. Create: Image #6335656
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id4932760376374165180.jpeg/orig
    38. Create: Preview image #6335657
      URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3811597316087843613.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:40
    Name: Neva Lux 7211; Catalog: Heating boilers