Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:22:26
Create:
Description #3470821
Value: Type of heating boiler: gas, max. thermal power: 11 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3470822
Value: Gas, convection
Create:
Burner #3470823
Value: Gas
Create:
Number of circuits #3470824
Value: Double-circuit, bithermic heat exchanger
Create:
Max. thermal power #3470825
Value: 11 kW
Create:
Max. thermal load #3470826
Value: 12.70 kW
Create:
The combustion chamber #3470827
Value: Closed
Create:
Heated area #3470828
Value: 110 sq.m
Create:
Efficiency #3470829
Value: 92.5 %
Create:
Control #3470830
Value: Electronic
Create:
Installation #3470831
Value: Wall-mounted
Create:
Primary heat exchanger material #3470832
Value: Copper
Create:
Mains voltage #3470833
Value: Single-phase
Create:
Peculiarities #3470834
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
Create:
Expansion tank volume #3470835
Value: 6 l
Create:
Equipment #3470836
Value: Display
Create:
Fuel #3470837
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3470838
Value: 1.3 cu. m/hour
Create:
LPG consumption #3470839
Value: 1 kg/hour
Create:
Nominal pressure of natural gas #3470840
Value: 13 - 20 mbar
Create:
Permissible LPG pressure #3470841
Value: 29 mbar
Create:
Heat carrier temperature #3470842
Value: 30 - 85 °С
Create:
Temperature in the DHW circuit #3470843
Value: 30 - 60 °С
Create:
Hot water capacity at t 25°C #3470844
Value: 9 l/min
Create:
Max. water pressure in the DHW circuit #3470845
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3470846
Value: 3 bar
Create:
Gas connection #3470847
Value: 3/4"
Create:
Heating circuit connection #3470848
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3470849
Value: 1/2"
Create:
Coaxial chimney diameter #3470850
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3470851
Value: Yes
Create:
Dimensions WxHxD #3470852
Value: 380x680x250mm
Create:
Additional Information #3470853
Value: Turbocharged
Create:
Image #6335653
URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3811597316087843613.jpeg/orig
Create:
Image #6335654
URL: https://avatars.mds.yandex.net/get-mpic/3725687/img_id1093441972428101517.jpeg/orig
Create:
Image #6335655
URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id7251591260513451069.png/orig
Create:
Image #6335656
URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id4932760376374165180.jpeg/orig
Create:
Preview image #6335657
URL: https://avatars.mds.yandex.net/get-mpic/4700988/img_id3811597316087843613.jpeg/orig
Donny Darko 30 April 2023 08:41:40
Name: Neva Lux 7211; Catalog: Heating boilers