Change history for item: Neva Lux 8624 24 kW double-circuit

  1. Donny Darko 08 July 2023 12:22:22
    1. Create: Description #3470790
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3470791
      Value: Gas, convection
    3. Create: Burner #3470792
      Value: Gas
    4. Create: Number of circuits #3470793
      Value: Double-circuit
    5. Create: Max. thermal power #3470794
      Value: 24 kW
    6. Create: Max. thermal load #3470795
      Value: 26.10 kW
    7. Create: The combustion chamber #3470796
      Value: Open
    8. Create: Efficiency #3470797
      Value: 92 %
    9. Create: Control #3470798
      Value: Electronic
    10. Create: Installation #3470799
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3470800
      Value: Copper
    12. Create: Mains voltage #3470801
      Value: Single-phase
    13. Create: Peculiarities #3470802
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3470803
      Value: 6 l
    15. Create: Equipment #3470804
      Value: Display
    16. Create: Fuel #3470805
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3470806
      Value: 2.56 cu. m/hour
    18. Create: LPG consumption #3470807
      Value: 2.06 kg/h
    19. Create: Nominal pressure of natural gas #3470808
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3470809
      Value: 29 mbar
    21. Create: Heat carrier temperature #3470810
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3470811
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3470812
      Value: 14 l/min
    24. Create: Max. water pressure in the DHW circuit #3470813
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3470814
      Value: 3 bar
    26. Create: Gas connection #3470815
      Value: 3/4"
    27. Create: Heating circuit connection #3470816
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3470817
      Value: 1/2"
    29. Create: Chimney diameter #3470818
      Value: 140 mm
    30. Create: Dimensions WxHxD #3470819
      Value: 410x720x326mm
    31. Create: Weight #3470820
      Value: 28 kg
    32. Create: Image #6335651
      URL: https://avatars.mds.yandex.net/get-mpic/4343007/img_id5740863957927060395.jpeg/orig
    33. Create: Preview image #6335652
      URL: https://avatars.mds.yandex.net/get-mpic/4343007/img_id5740863957927060395.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:40
    Name: Neva Lux 8624 24 kW double-circuit; Catalog: Heating boilers