Change history for item: Neva Lux 8230

  1. Donny Darko 08 July 2023 12:22:18
    1. Create: Description #3470758
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3470759
      Value: Gas, convection
    3. Create: Burner #3470760
      Value: Gas
    4. Create: Number of circuits #3470761
      Value: Double-circuit
    5. Create: Max. thermal power #3470762
      Value: 30 kW
    6. Create: Max. thermal load #3470763
      Value: 33 kW
    7. Create: The combustion chamber #3470764
      Value: Closed
    8. Create: Efficiency #3470765
      Value: 92.5 %
    9. Create: Control #3470766
      Value: Electronic
    10. Create: Installation #3470767
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3470768
      Value: Copper
    12. Create: Mains voltage #3470769
      Value: Single-phase
    13. Create: Peculiarities #3470770
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Expansion tank volume #3470771
      Value: 6 l
    15. Create: Equipment #3470772
      Value: Display
    16. Create: Fuel #3470773
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3470774
      Value: 3.43 cu. m/hour
    18. Create: LPG consumption #3470775
      Value: 2.61 kg/hour
    19. Create: Nominal pressure of natural gas #3470776
      Value: 13 - 20 mbar
    20. Create: Permissible LPG pressure #3470777
      Value: 29 mbar
    21. Create: Heat carrier temperature #3470778
      Value: 30 - 85 °С
    22. Create: Temperature in the DHW circuit #3470779
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3470780
      Value: 17 l/min
    24. Create: Max. water pressure in the DHW circuit #3470781
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3470782
      Value: 3 bar
    26. Create: Gas connection #3470783
      Value: 3/4"
    27. Create: Heating circuit connection #3470784
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3470785
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3470786
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3470787
      Value: Yes
    31. Create: Dimensions WxHxD #3470788
      Value: 410x720x326mm
    32. Create: Weight #3470789
      Value: 35 kg
    33. Create: Image #6335649
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id8785299051049049916.jpeg/orig
    34. Create: Preview image #6335650
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id8785299051049049916.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:40
    Name: Neva Lux 8230; Catalog: Heating boilers