Change history for item: Neva Lux 7218 18 kW double-circuit

  1. Donny Darko 08 July 2023 12:21:36
    1. Create: Description #3470605
      Value: Type of heating boiler: gas, max. thermal power: 18 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3470606
      Value: Gas, convection
    3. Create: Burner #3470607
      Value: Gas
    4. Create: Number of circuits #3470608
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3470609
      Value: 8.90 - 18 kW
    6. Create: Max. thermal load #3470610
      Value: 20 kW
    7. Create: The combustion chamber #3470611
      Value: Closed
    8. Create: Heated area #3470612
      Value: 180 sq.m
    9. Create: Efficiency #3470613
      Value: 92.5 %
    10. Create: Control #3470614
      Value: Electronic
    11. Create: Installation #3470615
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3470616
      Value: Copper
    13. Create: Mains voltage #3470617
      Value: Single-phase
    14. Create: Peculiarities #3470618
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    15. Create: Expansion tank volume #3470619
      Value: 6 l
    16. Create: Equipment #3470620
      Value: Display
    17. Create: Fuel #3470621
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3470622
      Value: 2.12 cu. m/hour
    19. Create: LPG consumption #3470623
      Value: 1.58 kg/h
    20. Create: Nominal pressure of natural gas #3470624
      Value: 13 - 20 mbar
    21. Create: Permissible LPG pressure #3470625
      Value: 29 mbar
    22. Create: Heat carrier temperature #3470626
      Value: 30 - 85 °С
    23. Create: Temperature in the DHW circuit #3470627
      Value: 30 - 60 °С
    24. Create: Hot water capacity at t 25°C #3470628
      Value: 14 l/min
    25. Create: Max. water pressure in the DHW circuit #3470629
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3470630
      Value: 3 bar
    27. Create: Gas connection #3470631
      Value: 3/4"
    28. Create: Heating circuit connection #3470632
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3470633
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3470634
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3470635
      Value: Yes
    32. Create: Dimensions WxHxD #3470636
      Value: 380x680x250mm
    33. Create: Additional Information #3470637
      Value: Turbocharged
    34. Create: Image #6335612
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id6138919152054250871.jpeg/orig
    35. Create: Image #6335613
      URL: https://avatars.mds.yandex.net/get-mpic/5236108/img_id5280205749582056297.jpeg/orig
    36. Create: Image #6335614
      URL: https://avatars.mds.yandex.net/get-mpic/1749547/img_id7251591260513451069.png/orig
    37. Create: Image #6335615
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id4932760376374165180.jpeg/orig
    38. Create: Preview image #6335616
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id6138919152054250871.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:39
    Name: Neva Lux 7218 18 kW double-circuit; Catalog: Heating boilers