Change history for item: Neva Lux 8224

  1. Donny Darko 08 July 2023 12:21:32
    1. Create: Description #3470571
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3470572
      Value: Gas, convection
    3. Create: Burner #3470573
      Value: Gas
    4. Create: Number of circuits #3470574
      Value: Double-circuit
    5. Create: Thermal power #3470575
      Value: 8.90 - 24 kW
    6. Create: Max. thermal load #3470576
      Value: 26.70 kW
    7. Create: The combustion chamber #3470577
      Value: Closed
    8. Create: Heated area #3470578
      Value: 240 sq.m
    9. Create: Efficiency #3470579
      Value: 92 %
    10. Create: Control #3470580
      Value: Electronic
    11. Create: Installation #3470581
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3470582
      Value: Copper
    13. Create: Secondary heat exchanger material #3470583
      Value: Stainless steel
    14. Create: Mains voltage #3470584
      Value: Single-phase
    15. Create: Peculiarities #3470585
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    16. Create: Expansion tank volume #3470586
      Value: 6 l
    17. Create: Equipment #3470587
      Value: Display
    18. Create: Fuel #3470588
      Value: Natural gas, liquefied gas
    19. Create: Natural gas consumption #3470589
      Value: 2.7 cu. m/hour
    20. Create: LPG consumption #3470590
      Value: 1.8 kg/hour
    21. Create: Nominal pressure of natural gas #3470591
      Value: 13 - 20 mbar
    22. Create: Permissible LPG pressure #3470592
      Value: 29 mbar
    23. Create: Heat carrier temperature #3470593
      Value: 30 - 80 °С
    24. Create: Temperature in the DHW circuit #3470594
      Value: 30 - 60 °С
    25. Create: Hot water capacity at t 25°C #3470595
      Value: 13.5 l/min
    26. Create: Max. water pressure in the DHW circuit #3470596
      Value: 10 bar
    27. Create: Max. water pressure in the heating circuit #3470597
      Value: 3 bar
    28. Create: Gas connection #3470598
      Value: 3/4"
    29. Create: Heating circuit connection #3470599
      Value: 3/4"
    30. Create: Branch pipe for connecting the DHW circuit #3470600
      Value: 1/2"
    31. Create: Coaxial chimney diameter #3470601
      Value: 60/100 mm
    32. Create: Connection of a separate chimney diameter 80 mm #3470602
      Value: Yes
    33. Create: Dimensions WxHxD #3470603
      Value: 370x670x250mm
    34. Create: Weight #3470604
      Value: 27 kg
    35. Create: Image #6335609
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id4802643983937557315.jpeg/orig
    36. Create: Image #6335610
      URL: https://avatars.mds.yandex.net/get-mpic/1565610/img_id1990122250522774827.jpeg/orig
    37. Create: Preview image #6335611
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id4802643983937557315.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:39
    Name: Neva Lux 8224; Catalog: Heating boilers