Change history for item: Convection gas boiler Navien DELUXE COAXIAL 20K, 20 kW, double-circuit

  1. Donny Darko 08 July 2023 12:14:19
    1. Create: Description #3469773
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3469774
      Value: Gas, convection
    3. Create: Burner #3469775
      Value: Gas
    4. Create: Number of circuits #3469776
      Value: Double-circuit
    5. Create: Thermal power #3469777
      Value: 9 - 20 kW
    6. Create: The combustion chamber #3469778
      Value: Closed
    7. Create: Heated area #3469779
      Value: 200 sq.m
    8. Create: Efficiency #3469780
      Value: 91.7 %
    9. Create: Control #3469781
      Value: Electronic
    10. Create: Installation #3469782
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3469783
      Value: Stainless steel
    12. Create: Mains voltage #3469784
      Value: Single-phase
    13. Create: Peculiarities #3469785
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Equipment #3469786
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3469787
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3469788
      Value: 2.15 cu. m/hour
    17. Create: LPG consumption #3469789
      Value: 1.79 kg/h
    18. Create: Nominal pressure of natural gas #3469790
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3469791
      Value: 28 mbar
    20. Create: Heat carrier temperature #3469792
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3469793
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3469794
      Value: 13.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3469795
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3469796
      Value: 3 bar
    25. Create: Gas connection #3469797
      Value: 1/2"
    26. Create: Heating circuit connection #3469798
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3469799
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3469800
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3469801
      Value: Yes
    30. Create: Dimensions WxHxD #3469802
      Value: 440x695x265 mm
    31. Create: Weight #3469803
      Value: 28 kg
    32. Create: Image #6335111
      URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id8387388461407846991/orig
    33. Create: Preview image #6335112
      URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id8387388461407846991/orig
  2. Donny Darko 30 April 2023 08:41:18
    Name: Convection gas boiler Navien DELUXE COAXIAL 20K, 20 kW, double-circuit; Catalog: Heating boilers