Change history for item: Gas wall-mounted boiler NAVIEN TURBO HEATLUXE NGB210-10K coaxial double-circuit

  1. Donny Darko 08 July 2023 12:11:22
    1. Create: Width #33175
      Value: 445
    2. Create: Height #33176
      Value: 770
    3. Create: Description #3468902
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    4. Create: Type of heating boiler #3468903
      Value: Gas
    5. Create: Number of circuits #3468904
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3468905
      Value: Convection
    7. Create: Combustion chamber type #3468906
      Value: Closed
    8. Create: Primary heat exchanger material #3468907
      Value: Stainless steel
    9. Create: Accommodation #3468908
      Value: Wall
    10. Create: Power type #3468909
      Value: Single-phase
    11. Create: Control #3468910
      Value: Electronic
    12. Create: Functions #3468911
      Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, power on indication
    13. Create: Minimum heat output #3468912
      Value: 8 kW
    14. Create: Max. thermal power #3468913
      Value: 100 kW
    15. Create: Minimum heat load #3468914
      Value: 6 kW
    16. Create: Maximum thermal load #3468915
      Value: 13 kW
    17. Create: Efficiency #3468916
      Value: 92 %
    18. Create: Heated area #3468917
      Value: 100 m²
    19. Create: Maximum water pressure in the heating circuit #3468918
      Value: 3 bar
    20. Create: Minimum heating medium temperature #3468919
      Value: 40°C
    21. Create: Maximum coolant temperature #3468920
      Value: 80°C
    22. Create: Number of power steps #3468921
      Value: 3
    23. Create: Expansion tank volume #3468922
      Value: 6 l
    24. Create: Gas connection #3468923
      Value: 3/4"
    25. Create: Heating circuit connection #3468924
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3468925
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3468926
      Value: 60/100 mm
    28. Create: Burner #3468927
      Value: Gas
    29. Create: Secondary heat exchanger material #3468928
      Value: Stainless steel
    30. Create: Minimum temperature in the DHW circuit #3468929
      Value: 35°C
    31. Create: Maximum temperature in the DHW circuit #3468930
      Value: 60°C
    32. Create: Maximum water pressure in the DHW circuit #3468931
      Value: 8 bar
    33. Create: Fuel for automatic feeding #3468932
      Value: Gas
    34. Create: Fuel #3468933
      Value: Natural gas, liquefied gas
    35. Create: Hot water capacity at t 25°C #3468934
      Value: 13.2 l/min
    36. Create: Hot water capacity at t 40°C #3468935
      Value: 8.3 l/min
    37. Create: Natural gas consumption #3468936
      Value: 1.54 m³/h
    38. Create: LPG consumption #3468937
      Value: 1.17 kg/h
    39. Create: Depth #3468938
      Value: 280 mm
    40. Create: Weight #3468939
      Value: 31 kg
    41. Create: Image #6334804
      URL: https://avatars.mds.yandex.net/get-mpic/1687058/img_id3325424474814797538.jpeg/orig
    42. Create: Image #6334805
      URL: https://avatars.mds.yandex.net/get-mpic/5283122/img_id2007496113467234466.jpeg/orig
    43. Create: Image #6334806
      URL: https://avatars.mds.yandex.net/get-mpic/4884224/img_id2790968914317581383.jpeg/orig
    44. Create: Image #6334807
      URL: https://avatars.mds.yandex.net/get-mpic/3934197/img_id8357881724008515037.png/orig
    45. Create: Image #6334808
      URL: https://avatars.mds.yandex.net/get-mpic/4776349/img_id5099833568337347493.jpeg/orig
    46. Create: Preview image #6334809
      URL: https://avatars.mds.yandex.net/get-mpic/1687058/img_id3325424474814797538.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:06
    Name: Gas wall-mounted boiler NAVIEN TURBO HEATLUXE NGB210-10K coaxial double-circuit; Catalog: Heating boilers