Change history for item: Gas wall-mounted boiler NAVIEN TURBO HEATLUXE NGB210-13K coaxial double-circuit

  1. Donny Darko 08 July 2023 12:10:01
    1. Create: Description #3468641
      Value: Type of heating boiler: gas, max. thermal power: 13 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3468642
      Value: Gas, convection
    3. Create: Burner #3468643
      Value: Gas
    4. Create: Number of circuits #3468644
      Value: Double-circuit
    5. Create: Thermal power #3468645
      Value: 8 - 13 kW
    6. Create: Thermal load #3468646
      Value: 6 - 13 kW
    7. Create: The combustion chamber #3468647
      Value: Closed
    8. Create: Heated area #3468648
      Value: 130 sq.m
    9. Create: Efficiency #3468649
      Value: 92 %
    10. Create: Control #3468650
      Value: Electronic
    11. Create: Installation #3468651
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3468652
      Value: Stainless steel
    13. Create: Secondary heat exchanger material #3468653
      Value: Stainless steel
    14. Create: Power steps #3468654
      Value: 3
    15. Create: Mains voltage #3468655
      Value: Single-phase
    16. Create: Peculiarities #3468656
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer, water filter
    17. Create: Expansion tank volume #3468657
      Value: 6 l
    18. Create: Equipment #3468658
      Value: Built-in exhaust fan, display
    19. Create: Fuel for automatic feeding #3468659
      Value: Gas
    20. Create: Fuel #3468660
      Value: Natural gas, liquefied gas
    21. Create: Natural gas consumption #3468661
      Value: 1.54 cu. m/hour
    22. Create: LPG consumption #3468662
      Value: 1.17 kg/hour
    23. Create: Heat carrier temperature #3468663
      Value: 40 - 80 °С
    24. Create: Temperature in the DHW circuit #3468664
      Value: 35 - 60 °С
    25. Create: Hot water capacity at t 25°C #3468665
      Value: 13.2 l/min
    26. Create: Hot water capacity at t 40°C #3468666
      Value: 8.3 l/min
    27. Create: Max. water pressure in the DHW circuit #3468667
      Value: 8 bar
    28. Create: Max. water pressure in the heating circuit #3468668
      Value: 3 bar
    29. Create: Gas connection #3468669
      Value: 3/4"
    30. Create: Heating circuit connection #3468670
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3468671
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3468672
      Value: 60/100 mm
    33. Create: Dimensions WxHxD #3468673
      Value: 445x770x280 mm
    34. Create: Weight #3468674
      Value: 31 kg
    35. Create: Image #6334714
      URL: https://avatars.mds.yandex.net/get-mpic/7389277/img_id8190140464138869172.jpeg/orig
    36. Create: Image #6334715
      URL: https://avatars.mds.yandex.net/get-mpic/1345185/img_id786398969113648618.jpeg/orig
    37. Create: Image #6334716
      URL: https://avatars.mds.yandex.net/get-mpic/5032583/img_id2040961272152935636.jpeg/orig
    38. Create: Image #6334717
      URL: https://avatars.mds.yandex.net/get-mpic/5387588/img_id7237019138152122942.jpeg/orig
    39. Create: Image #6334718
      URL: https://avatars.mds.yandex.net/get-mpic/5222168/img_id6285682616692381174.jpeg/orig
    40. Create: Image #6334719
      URL: https://avatars.mds.yandex.net/get-mpic/4923482/img_id7880147359465264153.jpeg/orig
    41. Create: Image #6334720
      URL: https://avatars.mds.yandex.net/get-mpic/4553373/img_id7239363153290351833.jpeg/orig
    42. Create: Image #6334721
      URL: https://avatars.mds.yandex.net/get-mpic/7388241/img_id1050837739982773873.jpeg/orig
    43. Create: Image #6334722
      URL: https://avatars.mds.yandex.net/get-mpic/4884224/img_id2790968914317581383.jpeg/orig
    44. Create: Image #6334723
      URL: https://avatars.mds.yandex.net/get-mpic/7979606/img_id4799304034507095596.jpeg/orig
    45. Create: Preview image #6334724
      URL: https://avatars.mds.yandex.net/get-mpic/7389277/img_id8190140464138869172.jpeg/orig
  2. Donny Darko 30 April 2023 08:41:02