Change history for item: 2-circuit gas wall-mounted boiler NAVIEN DELUXE S COAXIAL-40K

  1. Donny Darko 08 July 2023 12:08:08
    1. Create: Width #33153
      Value: 440
    2. Create: Height #33154
      Value: 665
    3. Create: Description #3468304
      Value: Type of heating boiler: gas, max. thermal power: 40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    4. Create: Type of heating boiler #3468305
      Value: Gas
    5. Create: Number of circuits #3468306
      Value: Double-circuit
    6. Create: The principle of operation of a gas boiler #3468307
      Value: Convection
    7. Create: Combustion chamber type #3468308
      Value: Closed
    8. Create: Primary heat exchanger material #3468309
      Value: Stainless steel
    9. Create: Accommodation #3468310
      Value: Wall
    10. Create: Power type #3468311
      Value: Single-phase
    11. Create: Control #3468312
      Value: Electronic
    12. Create: Equipment #3468313
      Value: Display, room thermostat, remote control
    13. Create: Functions #3468314
      Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, flame modulation
    14. Create: Minimum heat output #3468315
      Value: 12 kW
    15. Create: Max. thermal power #3468316
      Value: 40 kW
    16. Create: Minimum heat load #3468317
      Value: 12 kW
    17. Create: Maximum thermal load #3468318
      Value: 40 kW
    18. Create: Efficiency #3468319
      Value: 92 %
    19. Create: Heated area #3468320
      Value: 400 m²
    20. Create: Maximum water pressure in the heating circuit #3468321
      Value: 3 bar
    21. Create: Minimum heating medium temperature #3468322
      Value: 40°C
    22. Create: Maximum coolant temperature #3468323
      Value: 80°C
    23. Create: Expansion tank volume #3468324
      Value: 8 l
    24. Create: Gas connection #3468325
      Value: 3/4"
    25. Create: Heating circuit connection #3468326
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3468327
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3468328
      Value: 60/100 mm
    28. Create: Burner #3468329
      Value: Gas
    29. Create: Secondary heat exchanger material #3468330
      Value: Stainless steel
    30. Create: Minimum temperature in the DHW circuit #3468331
      Value: 30°C
    31. Create: Maximum temperature in the DHW circuit #3468332
      Value: 60°C
    32. Create: Maximum water pressure in the DHW circuit #3468333
      Value: 8 bar
    33. Create: Fuel #3468334
      Value: Natural gas, liquefied gas
    34. Create: Fuel consumption #3468335
      Value: 1.063 kg/h
    35. Create: Hot water capacity at t 25°C #3468336
      Value: 20.1 l/min
    36. Create: Hot water capacity at t 40°C #3468337
      Value: 12.5 l/min
    37. Create: Nominal natural gas pressure min. #3468338
      Value: 10 mbar
    38. Create: Nominal pressure of natural gas #3468339
      Value: 25 mbar
    39. Create: Permissible LPG pressure #3468340
      Value: 37 mbar
    40. Create: Natural gas consumption #3468341
      Value: 1.273 m³/h
    41. Create: LPG consumption #3468342
      Value: 1.063 kg/h
    42. Create: Depth #3468343
      Value: 255 mm
    43. Create: Weight #3468344
      Value: 27 kg
    44. Create: Image #6334596
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7391112510815021520.jpeg/orig
    45. Create: Image #6334597
      URL: https://avatars.mds.yandex.net/get-mpic/5418200/img_id1051537487441177639.jpeg/orig
    46. Create: Image #6334598
      URL: https://avatars.mds.yandex.net/get-mpic/4577446/img_id5657112163735451030.jpeg/orig
    47. Create: Image #6334599
      URL: https://avatars.mds.yandex.net/get-mpic/5236357/img_id3268650184851369944.jpeg/orig
    48. Create: Image #6334600
      URL: https://avatars.mds.yandex.net/get-mpic/5235295/img_id4697345488404093015.jpeg/orig
    49. Create: Image #6334601
      URL: https://avatars.mds.yandex.net/get-mpic/4466428/img_id4829143554880640025.jpeg/orig
    50. Create: Image #6334602
      URL: https://avatars.mds.yandex.net/get-mpic/3913686/img_id4434176657802447706.png/orig
    51. Create: Image #6334603
      URL: https://avatars.mds.yandex.net/get-mpic/5209489/img_id1643650489159105351.jpeg/orig
    52. Create: Image #6334604
      URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id1894731112562793397.jpeg/orig
    53. Create: Preview image #6334605
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7391112510815021520.jpeg/orig
  2. Donny Darko 30 April 2023 08:40:59
    Name: 2-circuit gas wall-mounted boiler NAVIEN DELUXE S COAXIAL-40K; Catalog: Heating boilers