Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:08:08
Create:
Width #33153
Value: 440
Create:
Height #33154
Value: 665
Create:
Description #3468304
Value: Type of heating boiler: gas, max. thermal power: 40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3468305
Value: Gas
Create:
Number of circuits #3468306
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3468307
Value: Convection
Create:
Combustion chamber type #3468308
Value: Closed
Create:
Primary heat exchanger material #3468309
Value: Stainless steel
Create:
Accommodation #3468310
Value: Wall
Create:
Power type #3468311
Value: Single-phase
Create:
Control #3468312
Value: Electronic
Create:
Equipment #3468313
Value: Display, room thermostat, remote control
Create:
Functions #3468314
Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, flame modulation
Create:
Minimum heat output #3468315
Value: 12 kW
Create:
Max. thermal power #3468316
Value: 40 kW
Create:
Minimum heat load #3468317
Value: 12 kW
Create:
Maximum thermal load #3468318
Value: 40 kW
Create:
Efficiency #3468319
Value: 92 %
Create:
Heated area #3468320
Value: 400 m²
Create:
Maximum water pressure in the heating circuit #3468321
Value: 3 bar
Create:
Minimum heating medium temperature #3468322
Value: 40°C
Create:
Maximum coolant temperature #3468323
Value: 80°C
Create:
Expansion tank volume #3468324
Value: 8 l
Create:
Gas connection #3468325
Value: 3/4"
Create:
Heating circuit connection #3468326
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3468327
Value: 1/2"
Create:
Coaxial chimney diameter #3468328
Value: 60/100 mm
Create:
Burner #3468329
Value: Gas
Create:
Secondary heat exchanger material #3468330
Value: Stainless steel
Create:
Minimum temperature in the DHW circuit #3468331
Value: 30°C
Create:
Maximum temperature in the DHW circuit #3468332
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3468333
Value: 8 bar
Create:
Fuel #3468334
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3468335
Value: 1.063 kg/h
Create:
Hot water capacity at t 25°C #3468336
Value: 20.1 l/min
Create:
Hot water capacity at t 40°C #3468337
Value: 12.5 l/min
Create:
Nominal natural gas pressure min. #3468338
Value: 10 mbar
Create:
Nominal pressure of natural gas #3468339
Value: 25 mbar
Create:
Permissible LPG pressure #3468340
Value: 37 mbar
Create:
Natural gas consumption #3468341
Value: 1.273 m³/h
Create:
LPG consumption #3468342
Value: 1.063 kg/h
Create:
Depth #3468343
Value: 255 mm
Create:
Weight #3468344
Value: 27 kg
Create:
Image #6334596
URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7391112510815021520.jpeg/orig
Create:
Image #6334597
URL: https://avatars.mds.yandex.net/get-mpic/5418200/img_id1051537487441177639.jpeg/orig
Create:
Image #6334598
URL: https://avatars.mds.yandex.net/get-mpic/4577446/img_id5657112163735451030.jpeg/orig
Create:
Image #6334599
URL: https://avatars.mds.yandex.net/get-mpic/5236357/img_id3268650184851369944.jpeg/orig
Create:
Image #6334600
URL: https://avatars.mds.yandex.net/get-mpic/5235295/img_id4697345488404093015.jpeg/orig
Create:
Image #6334601
URL: https://avatars.mds.yandex.net/get-mpic/4466428/img_id4829143554880640025.jpeg/orig
Create:
Image #6334602
URL: https://avatars.mds.yandex.net/get-mpic/3913686/img_id4434176657802447706.png/orig
Create:
Image #6334603
URL: https://avatars.mds.yandex.net/get-mpic/5209489/img_id1643650489159105351.jpeg/orig
Create:
Image #6334604
URL: https://avatars.mds.yandex.net/get-mpic/364668/img_id1894731112562793397.jpeg/orig
Create:
Preview image #6334605
URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id7391112510815021520.jpeg/orig
Donny Darko 30 April 2023 08:40:59
Name: 2-circuit gas wall-mounted boiler NAVIEN DELUXE S COAXIAL-40K; Catalog: Heating boilers