Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 12:02:14
Create:
Width #33127
Value: 400
Create:
Height #33128
Value: 665
Create:
Description #3467088
Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3467089
Value: Gas
Create:
Number of circuits #3467090
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3467091
Value: Convection
Create:
Combustion chamber type #3467092
Value: Closed
Create:
Primary heat exchanger material #3467093
Value: Stainless steel
Create:
Accommodation #3467094
Value: Wall
Create:
Non-volatile #3467095
Value: There is
Create:
Power type #3467096
Value: Single-phase
Create:
Control #3467097
Value: Electronic
Create:
Equipment #3467098
Value: Display, room thermostat, remote control
Create:
Functions #3467099
Value: Self-diagnosis, auto-ignition, frost protection, overheating protection, flame modulation
Create:
Minimum heat output #3467100
Value: 8 kW
Create:
Max. thermal power #3467101
Value: 16 kW
Create:
Efficiency #3467102
Value: 91.4 %
Create:
Heated area #3467103
Value: 160 m²
Create:
Maximum water pressure in the heating circuit #3467104
Value: 3 bar
Create:
Minimum heating medium temperature #3467105
Value: 40°C
Create:
Maximum coolant temperature #3467106
Value: 80°C
Create:
Expansion tank volume #3467107
Value: 6 l
Create:
Gas connection #3467108
Value: 3/4"
Create:
Heating circuit connection #3467109
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3467110
Value: 1/2"
Create:
Chimney diameter #3467111
Value: 100 mm
Create:
Coaxial chimney diameter #3467112
Value: 60/100 mm
Create:
Separate chimney 80x80 mm #3467113
Value: There is
Create:
Burner #3467114
Value: Gas
Create:
Secondary heat exchanger material #3467115
Value: Stainless steel
Create:
Minimum temperature in the DHW circuit #3467116
Value: 30°C
Create:
Maximum temperature in the DHW circuit #3467117
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3467118
Value: 8 bar
Create:
Fuel for automatic feeding #3467119
Value: Gas
Create:
Fuel #3467120
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3467121
Value: 1.43 kg/h
Create:
Hot water capacity at t 25°C #3467122
Value: 13.8 l/min
Create:
Hot water capacity at t 30°C #3467123
Value: 13.8 l/min
Create:
Nominal natural gas pressure min. #3467124
Value: 10 mbar
Create:
Nominal pressure of natural gas #3467125
Value: 25 mbar
Create:
Permissible LPG pressure #3467126
Value: 37 mbar
Create:
Natural gas consumption #3467127
Value: 1.72 m³/h
Create:
LPG consumption #3467128
Value: 1.43 kg/h
Create:
Depth #3467129
Value: 255 mm
Create:
Weight #3467130
Value: 26 kg
Create:
Additional Information #3467131
Value: Made in Korea, 1 year warranty
Create:
Image #6334020
URL: https://avatars.mds.yandex.net/get-mpic/1970506/img_id2404505729933474002.jpeg/orig
Create:
Image #6334021
URL: https://avatars.mds.yandex.net/get-mpic/5288893/img_id4541904263638370443.jpeg/orig
Create:
Image #6334022
URL: https://avatars.mds.yandex.net/get-mpic/4565245/img_id5893048106597296757.jpeg/orig
Create:
Image #6334023
URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id6383124113389815926.jpeg/orig
Create:
Preview image #6334024
URL: https://avatars.mds.yandex.net/get-mpic/1970506/img_id2404505729933474002.jpeg/orig
Donny Darko 30 April 2023 08:40:43
Name: Gas wall-mounted boiler 2-circuit NAVIEN DELUXE С-16K COAXIAL; Catalog: Heating boilers