Change history for item: 2-circuit gas wall-mounted boiler NAVIEN DELUXE С-35K COAXIAL

  1. Donny Darko 08 July 2023 12:02:10
    1. Create: Width #33125
      Value: 440
    2. Create: Height #33126
      Value: 665
    3. Create: Description #3467053
      Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    4. Create: Type of heating boiler #3467054
      Value: Gas
    5. Create: Number of circuits #3467055
      Value: Double-circuit
    6. Create: Combustion chamber type #3467056
      Value: Closed
    7. Create: Primary heat exchanger material #3467057
      Value: Stainless steel
    8. Create: Accommodation #3467058
      Value: Wall
    9. Create: Power type #3467059
      Value: Single-phase
    10. Create: Control #3467060
      Value: Electronic
    11. Create: Equipment #3467061
      Value: Room thermostat
    12. Create: Functions #3467062
      Value: Auto diagnostics
    13. Create: Minimum heat output #3467063
      Value: 8 kW
    14. Create: Max. thermal power #3467064
      Value: 35 kW
    15. Create: Efficiency #3467065
      Value: 91.5 %
    16. Create: Heated area #3467066
      Value: 350 m²
    17. Create: Maximum water pressure in the heating circuit #3467067
      Value: 3 bar
    18. Create: Minimum heating medium temperature #3467068
      Value: 40°C
    19. Create: Maximum coolant temperature #3467069
      Value: 80°C
    20. Create: Gas connection #3467070
      Value: 3/4"
    21. Create: Heating circuit connection #3467071
      Value: 3/4"
    22. Create: Branch pipe for connecting the DHW circuit #3467072
      Value: 1/2"
    23. Create: Chimney diameter #3467073
      Value: 100 mm
    24. Create: Coaxial chimney diameter #3467074
      Value: 60/100 mm
    25. Create: Burner #3467075
      Value: Gas
    26. Create: Minimum temperature in the DHW circuit #3467076
      Value: 30°C
    27. Create: Maximum temperature in the DHW circuit #3467077
      Value: 60°C
    28. Create: Maximum water pressure in the DHW circuit #3467078
      Value: 8 bar
    29. Create: Fuel #3467079
      Value: Natural gas
    30. Create: Hot water capacity at t 40°C #3467080
      Value: 12.5 l/min
    31. Create: Nominal natural gas pressure min. #3467081
      Value: 10 mbar
    32. Create: Nominal pressure of natural gas #3467082
      Value: 25 mbar
    33. Create: Permissible LPG pressure #3467083
      Value: 37 mbar
    34. Create: Natural gas consumption #3467084
      Value: 3.77 m³/h
    35. Create: LPG consumption #3467085
      Value: 3.14 kg/h
    36. Create: Depth #3467086
      Value: 255 mm
    37. Create: Weight #3467087
      Value: 27 kg
    38. Create: Image #6334017
      URL: https://avatars.mds.yandex.net/get-mpic/6236983/img_id1505426391198133590.jpeg/orig
    39. Create: Image #6334018
      URL: https://avatars.mds.yandex.net/get-mpic/1930823/img_id2403385205770921649.jpeg/orig
    40. Create: Preview image #6334019
      URL: https://avatars.mds.yandex.net/get-mpic/6236983/img_id1505426391198133590.jpeg/orig
  2. Donny Darko 30 April 2023 08:40:43
    Name: 2-circuit gas wall-mounted boiler NAVIEN DELUXE С-35K COAXIAL; Catalog: Heating boilers