      Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3466094
      Value: Gas, convection
    3. Create: Burner #3466095
      Value: Gas
    4. Create: Number of circuits #3466096
      Value: Double-circuit
    5. Create: Thermal power #3466097
      Value: 13 - 35 kW
    6. Create: The combustion chamber #3466098
      Value: Closed
    7. Create: Heated area #3466099
      Value: 350 sq.m
    8. Create: Efficiency #3466100
      Value: 90.5 %
    9. Create: Control #3466101
      Value: Electronic
    10. Create: Installation #3466102
      Value: Wall-mounted
    11. Create: Mains voltage #3466103
      Value: Single-phase
    12. Create: Peculiarities #3466104
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3466105
      Value: Outdoor temperature sensor, display, room thermostat, remote control
    14. Create: Fuel #3466106
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3466107
      Value: 4.12 cu. m/hour
    16. Create: LPG consumption #3466108
      Value: 3.14 kg/h
    17. Create: Nominal pressure of natural gas #3466109
      Value: 10 - 25 mbar
    18. Create: Permissible LPG pressure #3466110
      Value: 28 mbar
    19. Create: Heat carrier temperature #3466111
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3466112
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3466113
      Value: 20.1 l/min
    22. Create: Hot water capacity at t 40°C #3466114
      Value: 12.5 l/min
    23. Create: Max. water pressure in the DHW circuit #3466115
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3466116
      Value: 3 bar
    25. Create: Gas connection #3466117
      Value: 3/4"
    26. Create: Heating circuit connection #3466118
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3466119
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3466120
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3466121
      Value: Yes
    30. Create: Dimensions WxHxD #3466122
      Value: 440x695x290 mm
    31. Create: Weight #3466123
      Value: 30 kg
    32. Create: Image #6333601
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4860372664193714105/orig
    33. Create: Image #6333602
      URL: https://avatars.mds.yandex.net/get-mpic/5315102/img_id8221015262576548043.jpeg/orig
    34. Create: Image #6333603
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id6781925139113586134.jpeg/orig
    35. Create: Preview image #6333604
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4860372664193714105/orig
  2. Donny Darko 30 April 2023 08:40:31
    Name: Gas boiler Navien SMART TOK 35K; Catalog: Heating boilers