Change history for item: Gas boiler Navien SMART TOK 30K

  1. Donny Darko 08 July 2023 11:55:49
    1. Create: Description #3466062
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3466063
      Value: Gas, convection
    3. Create: Burner #3466064
      Value: Gas
    4. Create: Number of circuits #3466065
      Value: Double-circuit
    5. Create: Thermal power #3466066
      Value: 11 - 30 kW
    6. Create: The combustion chamber #3466067
      Value: Closed
    7. Create: Heated area #3466068
      Value: 300 sq.m
    8. Create: Efficiency #3466069
      Value: 90.5 %
    9. Create: Control #3466070
      Value: Electronic
    10. Create: Installation #3466071
      Value: Wall-mounted
    11. Create: Mains voltage #3466072
      Value: Single-phase
    12. Create: Peculiarities #3466073
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3466074
      Value: Outdoor temperature sensor, display, room thermostat, remote control
    14. Create: Fuel #3466075
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3466076
      Value: 3.53 cu. m/hour
    16. Create: LPG consumption #3466077
      Value: 2.69 kg/h
    17. Create: Nominal pressure of natural gas #3466078
      Value: 10 - 25 mbar
    18. Create: Permissible LPG pressure #3466079
      Value: 28 mbar
    19. Create: Heat carrier temperature #3466080
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3466081
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3466082
      Value: 17.2 l/min
    22. Create: Hot water capacity at t 40°C #3466083
      Value: 10.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3466084
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3466085
      Value: 3 bar
    25. Create: Gas connection #3466086
      Value: 3/4"
    26. Create: Heating circuit connection #3466087
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3466088
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3466089
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3466090
      Value: Yes
    30. Create: Dimensions WxHxD #3466091
      Value: 440x695x290 mm
    31. Create: Weight #3466092
      Value: 29 kg
    32. Create: Image #6333599
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id4693110618725219733/orig
    33. Create: Preview image #6333600
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id4693110618725219733/orig
  2. Donny Darko 30 April 2023 08:40:30
    Name: Gas boiler Navien SMART TOK 30K; Catalog: Heating boilers