Change history for item: Gas boiler Navien SMART TOK 20K

  1. Donny Darko 08 July 2023 11:55:34
    1. Create: Description #3465938
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3465939
      Value: Gas, convection
    3. Create: Burner #3465940
      Value: Gas
    4. Create: Number of circuits #3465941
      Value: Double-circuit
    5. Create: Thermal power #3465942
      Value: 9 - 20 kW
    6. Create: The combustion chamber #3465943
      Value: Closed
    7. Create: Heated area #3465944
      Value: 200 sq.m
    8. Create: Efficiency #3465945
      Value: 91.7 %
    9. Create: Control #3465946
      Value: Electronic
    10. Create: Installation #3465947
      Value: Wall-mounted
    11. Create: Mains voltage #3465948
      Value: Single-phase
    12. Create: Peculiarities #3465949
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Equipment #3465950
      Value: Outdoor temperature sensor, display, room thermostat, remote control
    14. Create: Fuel #3465951
      Value: Natural gas, liquefied gas
    15. Create: Natural gas consumption #3465952
      Value: 2.32 cu. m/hour
    16. Create: LPG consumption #3465953
      Value: 1.79 kg/h
    17. Create: Nominal pressure of natural gas #3465954
      Value: 10 - 25 mbar
    18. Create: Permissible LPG pressure #3465955
      Value: 28 mbar
    19. Create: Heat carrier temperature #3465956
      Value: 40 - 80 °С
    20. Create: Temperature in the DHW circuit #3465957
      Value: 30 - 60 °С
    21. Create: Hot water capacity at t 25°C #3465958
      Value: 13.8 l/min
    22. Create: Hot water capacity at t 40°C #3465959
      Value: 8.6 l/min
    23. Create: Max. water pressure in the DHW circuit #3465960
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3465961
      Value: 3 bar
    25. Create: Gas connection #3465962
      Value: 1/2"
    26. Create: Heating circuit connection #3465963
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3465964
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3465965
      Value: 60/100 mm
    29. Create: Connection of a separate chimney diameter 80 mm #3465966
      Value: Yes
    30. Create: Dimensions WxHxD #3465967
      Value: 440x695x290 mm
    31. Create: Weight #3465968
      Value: 28 kg
    32. Create: Image #6333588
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id6409958766480048694/orig
    33. Create: Preview image #6333589
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id6409958766480048694/orig
  2. Donny Darko 30 April 2023 08:40:29
    Name: Gas boiler Navien SMART TOK 20K; Catalog: Heating boilers