Change history for item: Gas boiler Navien ACE COAXIAL 20KN 20 kW double-circuit

  1. Donny Darko 08 July 2023 11:54:42
    1. Create: Description #3465756
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3465757
      Value: Gas, convection
    3. Create: Burner #3465758
      Value: Gas
    4. Create: Number of circuits #3465759
      Value: Double-circuit
    5. Create: Thermal power #3465760
      Value: 9 - 20 kW
    6. Create: The combustion chamber #3465761
      Value: Closed
    7. Create: Heated area #3465762
      Value: 200 sq.m
    8. Create: Efficiency #3465763
      Value: 91.7 %
    9. Create: Control #3465764
      Value: Electronic
    10. Create: Installation #3465765
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3465766
      Value: Stainless steel
    12. Create: Mains voltage #3465767
      Value: Single-phase
    13. Create: Peculiarities #3465768
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    14. Create: Equipment #3465769
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3465770
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3465771
      Value: 2.15 cu. m/hour
    17. Create: LPG consumption #3465772
      Value: 1.79 kg/h
    18. Create: Nominal pressure of natural gas #3465773
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3465774
      Value: 28 mbar
    20. Create: Heat carrier temperature #3465775
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3465776
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3465777
      Value: 13.8 l/min
    23. Create: Hot water capacity at t 40°C #3465778
      Value: 8.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3465779
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3465780
      Value: 3 bar
    26. Create: Gas connection #3465781
      Value: 1/2"
    27. Create: Heating circuit connection #3465782
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3465783
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3465784
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3465785
      Value: 440x695x265 mm
    31. Create: Weight #3465786
      Value: 28 kg
    32. Create: Image #6333571
      URL: https://avatars.mds.yandex.net/get-mpic/1925356/img_id7254486790153136029/orig
    33. Create: Preview image #6333572
      URL: https://avatars.mds.yandex.net/get-mpic/1925356/img_id7254486790153136029/orig
  2. Donny Darko 30 April 2023 08:40:28
    Name: Gas boiler Navien ACE COAXIAL 20KN 20 kW double-circuit; Catalog: Heating boilers