Change history for item: Gas boiler Navien ACE COAXIAL 16KN 16 kW double-circuit

  1. Donny Darko 08 July 2023 11:54:38
    1. Create: Description #3465725
      Value: Type of heating boiler: gas, max. thermal power: 16 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3465726
      Value: Gas, convection
    3. Create: Burner #3465727
      Value: Gas
    4. Create: Number of circuits #3465728
      Value: Double-circuit
    5. Create: Thermal power #3465729
      Value: 9 - 16 kW
    6. Create: The combustion chamber #3465730
      Value: Closed
    7. Create: Heated area #3465731
      Value: 160 sq.m
    8. Create: Efficiency #3465732
      Value: 91.2 %
    9. Create: Control #3465733
      Value: Electronic
    10. Create: Installation #3465734
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3465735
      Value: Stainless steel
    12. Create: Mains voltage #3465736
      Value: Single-phase
    13. Create: Peculiarities #3465737
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    14. Create: Equipment #3465738
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3465739
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3465740
      Value: 1.72 cu. m/hour
    17. Create: LPG consumption #3465741
      Value: 1.43 kg/h
    18. Create: Nominal pressure of natural gas #3465742
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3465743
      Value: 28 mbar
    20. Create: Heat carrier temperature #3465744
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3465745
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3465746
      Value: 13.8 l/min
    23. Create: Hot water capacity at t 40°C #3465747
      Value: 8.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3465748
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3465749
      Value: 3 bar
    26. Create: Gas connection #3465750
      Value: 1/2"
    27. Create: Heating circuit connection #3465751
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3465752
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3465753
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3465754
      Value: 440x695x265 mm
    31. Create: Weight #3465755
      Value: 28 kg
    32. Create: Image #6333569
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2603948661244533279/orig
    33. Create: Preview image #6333570
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id2603948661244533279/orig
  2. Donny Darko 30 April 2023 08:40:27
    Name: Gas boiler Navien ACE COAXIAL 16KN 16 kW double-circuit; Catalog: Heating boilers