Change history for item: Gas boiler Navien NCB 34LSWE 28.3 kW double-circuit

  1. Donny Darko 08 July 2023 11:49:36
    1. Create: Description #3464565
      Value: Type of heating boiler: gas, max. thermal power: 28.30 kW, number of circuits: double-circuit, placement: wall-mounted, type of combustion chamber: closed, type of power supply: single-phase, control: electronic, operating principle
    2. Create: Type of heating boiler #3464566
      Value: Gas, condensing
    3. Create: Burner #3464567
      Value: Gas
    4. Create: Number of circuits #3464568
      Value: Double-circuit
    5. Create: Thermal power #3464569
      Value: 4.90 - 28.30 kW
    6. Create: Thermal load #3464570
      Value: 5.10 - 29 kW
    7. Create: The combustion chamber #3464571
      Value: Closed
    8. Create: Heated area #3464572
      Value: 270 sq.m
    9. Create: Efficiency #3464573
      Value: 106.9 %
    10. Create: Control #3464574
      Value: Electronic
    11. Create: Installation #3464575
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3464576
      Value: Stainless steel
    13. Create: Secondary heat exchanger material #3464577
      Value: Stainless steel
    14. Create: Mains voltage #3464578
      Value: Single-phase
    15. Create: Peculiarities #3464579
      Value: Built-in circulation pump, thermometer
    16. Create: Equipment #3464580
      Value: Remote control
    17. Create: Heat carrier temperature #3464581
      Value: 40 - 90 °С
    18. Create: Temperature in the DHW circuit #3464582
      Value: 30 - 65 °С
    19. Create: Hot water capacity at t 25°C #3464583
      Value: 19.5 l/min
    20. Create: Hot water capacity at t 30°C #3464584
      Value: 16.2 l/min
    21. Create: Hot water capacity at t 45°C #3464585
      Value: 10.8 l/min
    22. Create: Max. water pressure in the DHW circuit #3464586
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3464587
      Value: 2.5 bar
    24. Create: Gas connection #3464588
      Value: 3/4"
    25. Create: Heating circuit connection #3464589
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3464590
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3464591
      Value: 60/100 mm and 80/125 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3464592
      Value: Yes
    29. Create: Dimensions WxHxD #3464593
      Value: 440x695x290 mm
    30. Create: Weight #3464594
      Value: 42 kg
    31. Create: Image #6333401
      URL: https://avatars.mds.yandex.net/get-mpic/1733932/img_id7262185192904903891.jpeg/orig
    32. Create: Preview image #6333402
      URL: https://avatars.mds.yandex.net/get-mpic/1733932/img_id7262185192904903891.jpeg/orig
  2. Donny Darko 30 April 2023 08:40:16
    Name: Gas boiler Navien NCB 34LSWE 28.3 kW double-circuit; Catalog: Heating boilers