Change history for item: Gas boiler Navien NCB 40LSWE 33.2 kW double-circuit

  1. Donny Darko 08 July 2023 11:49:18
    1. Create: Description #3464475
      Value: Type of heating boiler: gas, max. thermal power: 33.20 kW, number of circuits: double-circuit, placement: wall-mounted, type of combustion chamber: closed, type of power supply: single-phase, control: electronic, operating principle
    2. Create: Type of heating boiler #3464476
      Value: Gas, condensing
    3. Create: Burner #3464477
      Value: Gas
    4. Create: Number of circuits #3464478
      Value: Double-circuit
    5. Create: Thermal power #3464479
      Value: 3.90 - 33.20 kW
    6. Create: Thermal load #3464480
      Value: 4 - 34 kW
    7. Create: The combustion chamber #3464481
      Value: Closed
    8. Create: Heated area #3464482
      Value: 317 sq.m
    9. Create: Efficiency #3464483
      Value: 95.8 %
    10. Create: Control #3464484
      Value: Electronic
    11. Create: Installation #3464485
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3464486
      Value: Stainless steel
    13. Create: Secondary heat exchanger material #3464487
      Value: Stainless steel
    14. Create: Mains voltage #3464488
      Value: Single-phase
    15. Create: Peculiarities #3464489
      Value: Built-in circulation pump, thermometer
    16. Create: Equipment #3464490
      Value: Display, remote control
    17. Create: Heat carrier temperature #3464491
      Value: 40 - 90 °С
    18. Create: Temperature in the DHW circuit #3464492
      Value: 30 - 65 °С
    19. Create: Hot water capacity at t 25°C #3464493
      Value: 22.9 l/min
    20. Create: Hot water capacity at t 30°C #3464494
      Value: 19.1 l/min
    21. Create: Hot water capacity at t 45°C #3464495
      Value: 12.7 l/min
    22. Create: Max. water pressure in the DHW circuit #3464496
      Value: 10 bar
    23. Create: Max. water pressure in the heating circuit #3464497
      Value: 2.5 bar
    24. Create: Gas connection #3464498
      Value: 3/4"
    25. Create: Heating circuit connection #3464499
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3464500
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3464501
      Value: 60/100 mm and 80/125 mm
    28. Create: Connection of a separate chimney diameter 80 mm #3464502
      Value: Yes
    29. Create: Dimensions WxHxD #3464503
      Value: 440x695x290 mm
    30. Create: Weight #3464504
      Value: 42 kg
    31. Create: Image #6333395
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id5184378777551306459.jpeg/orig
    32. Create: Preview image #6333396
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id5184378777551306459.jpeg/orig
  2. Donny Darko 30 April 2023 08:40:15
    Name: Gas boiler Navien NCB 40LSWE 33.2 kW double-circuit; Catalog: Heating boilers