Change history for item: Gas boiler Navien PRIME 30K

  1. Donny Darko 08 July 2023 11:48:53
    1. Create: Description #3464305
      Value: Type of heating boiler: gas, max. thermal power: 30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3464306
      Value: Gas, convection
    3. Create: Burner #3464307
      Value: Gas
    4. Create: Number of circuits #3464308
      Value: Double-circuit
    5. Create: Thermal power #3464309
      Value: 11 - 30 kW
    6. Create: The combustion chamber #3464310
      Value: Closed
    7. Create: Heated area #3464311
      Value: 300 sq.m
    8. Create: Efficiency #3464312
      Value: 90.5 %
    9. Create: Control #3464313
      Value: Electronic
    10. Create: Installation #3464314
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3464315
      Value: Stainless steel
    12. Create: Mains voltage #3464316
      Value: Single-phase
    13. Create: Peculiarities #3464317
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Equipment #3464318
      Value: Display
    15. Create: Fuel #3464319
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3464320
      Value: 3.53 cu. m/hour
    17. Create: LPG consumption #3464321
      Value: 2.69 kg/h
    18. Create: Nominal pressure of natural gas #3464322
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3464323
      Value: 28 mbar
    20. Create: Heat carrier temperature #3464324
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3464325
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3464326
      Value: 17.2 l/min
    23. Create: Hot water capacity at t 40°C #3464327
      Value: 10.8 l/min
    24. Create: Max. water pressure in the DHW circuit #3464328
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3464329
      Value: 3 bar
    26. Create: Gas connection #3464330
      Value: 3/4"
    27. Create: Heating circuit connection #3464331
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3464332
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3464333
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3464334
      Value: Yes
    31. Create: Dimensions WxHxD #3464335
      Value: 440x695x265 mm
    32. Create: Weight #3464336
      Value: 29 kg
    33. Create: Additional Information #3464337
      Value: Smart remote control with voice assistant option
    34. Create: Image #6333383
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4517149104623302443/orig
    35. Create: Preview image #6333384
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4517149104623302443/orig
  2. Donny Darko 30 April 2023 08:40:14
    Name: Gas boiler Navien PRIME 30K; Catalog: Heating boilers