    1. Create: Description #3464238
      Value: Type of heating boiler: gas, max. thermal power: 20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3464239
      Value: Gas, convection
    3. Create: Burner #3464240
      Value: Gas
    4. Create: Number of circuits #3464241
      Value: Double-circuit
    5. Create: Thermal power #3464242
      Value: 8 - 20 kW
    6. Create: The combustion chamber #3464243
      Value: Closed
    7. Create: Heated area #3464244
      Value: 200 sq.m
    8. Create: Efficiency #3464245
      Value: 91.7 %
    9. Create: Control #3464246
      Value: Electronic
    10. Create: Installation #3464247
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3464248
      Value: Stainless steel
    12. Create: Mains voltage #3464249
      Value: Single-phase
    13. Create: Peculiarities #3464250
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Equipment #3464251
      Value: Display
    15. Create: Fuel #3464252
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3464253
      Value: 2.32 cu. m/hour
    17. Create: LPG consumption #3464254
      Value: 1.79 kg/h
    18. Create: Nominal pressure of natural gas #3464255
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3464256
      Value: 28 mbar
    20. Create: Heat carrier temperature #3464257
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3464258
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3464259
      Value: 13.8 l/min
    23. Create: Hot water capacity at t 40°C #3464260
      Value: 8.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3464261
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3464262
      Value: 3 bar
    26. Create: Gas connection #3464263
      Value: 1/2"
    27. Create: Heating circuit connection #3464264
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3464265
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3464266
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3464267
      Value: Yes
    31. Create: Dimensions WxHxD #3464268
      Value: 440x695x265 mm
    32. Create: Weight #3464269
      Value: 28 kg
    33. Create: Additional Information #3464270
      Value: Smart remote control with voice assistant option