- Donny Darko 08 July 2023 11:48:42
-
Create:
Peculiarities #3464304
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
- Donny Darko 08 July 2023 11:48:16
-
Create:
Description #3464202
Value: Boiler type: gas, number of circuits: two-circuit, max. heat output: 16 kW, heated area: 160 m², placement: wall-mounted, electrical network type: single-phase, combustion chamber type: closed,
-
Create:
Type of heating boiler #3464203
Value: Gas, convection
-
Create:
Burner #3464204
Value: Gas
-
Create:
Number of circuits #3464205
Value: Double-circuit
-
Create:
Thermal power #3464206
Value: 8 - 16 kW
-
Create:
The combustion chamber #3464207
Value: Closed
-
Create:
Heated area #3464208
Value: 160 sq.m
-
Create:
Efficiency #3464209
Value: 92 %
-
Create:
Control #3464210
Value: Electronic
-
Create:
Installation #3464211
Value: Wall-mounted
-
Create:
Primary heat exchanger material #3464212
Value: Stainless steel
-
Create:
Mains voltage #3464213
Value: Single-phase
-
Create:
Built-in circulation pump #3464214
Value: There is
-
Create:
Built-in expansion tank #3464215
Value: There is
-
Create:
Equipment #3464216
Value: Display
-
Create:
Fuel #3464217
Value: Natural gas, liquefied gas
-
Create:
Natural gas consumption #3464218
Value: 1.86 cu. m/hour
-
Create:
LPG consumption #3464219
Value: 1.43 kg/h
-
Create:
Nominal pressure of natural gas #3464220
Value: 10 - 25 mbar
-
Create:
Permissible LPG pressure #3464221
Value: 28 mbar
-
Create:
Heat carrier temperature #3464222
Value: 40 - 80 °С
-
Create:
Temperature in the DHW circuit #3464223
Value: 30 - 60 °С
-
Create:
Hot water capacity at t 25°C #3464224
Value: 13.8 l/min
-
Create:
Hot water capacity at t 40°C #3464225
Value: 8.6 l/min
-
Create:
Max. water pressure in the DHW circuit #3464226
Value: 8 bar
-
Create:
Max. water pressure in the heating circuit #3464227
Value: 3 bar
-
Create:
Functions #3464228
Value: Frost protection, thermometer, manometer
-
Create:
Protection #3464229
Value: Gas control, safety valve, air vent
-
Create:
Gas connection #3464230
Value: 1/2"
-
Create:
Heating circuit connection #3464231
Value: 3/4"
-
Create:
Branch pipe for connecting the DHW circuit #3464232
Value: 1/2"
-
Create:
Coaxial chimney diameter #3464233
Value: 60/100 mm
-
Create:
Connection of a separate chimney diameter 80 mm #3464234
Value: Yes
-
Create:
Dimensions WxHxD #3464235
Value: 440x695x265 mm
-
Create:
Weight #3464236
Value: 28 kg
-
Create:
Additional Information #3464237
Value: Smart remote control with voice assistant option
-
Create:
Image #6333377
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1327470495532401926/orig
-
Create:
Preview image #6333378
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1327470495532401926/orig
- Donny Darko 30 April 2023 08:40:13
Name: Gas boiler Navien PRIME 16K; Catalog: Heating boilers