Change history for item: Gas boiler Navien PRIME 16K

  1. Donny Darko 08 July 2023 11:48:42
    1. Create: Peculiarities #3464304
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
  2. Donny Darko 08 July 2023 11:48:16
    1. Create: Description #3464202
      Value: Boiler type: gas, number of circuits: two-circuit, max. heat output: 16 kW, heated area: 160 m², placement: wall-mounted, electrical network type: single-phase, combustion chamber type: closed,
    2. Create: Type of heating boiler #3464203
      Value: Gas, convection
    3. Create: Burner #3464204
      Value: Gas
    4. Create: Number of circuits #3464205
      Value: Double-circuit
    5. Create: Thermal power #3464206
      Value: 8 - 16 kW
    6. Create: The combustion chamber #3464207
      Value: Closed
    7. Create: Heated area #3464208
      Value: 160 sq.m
    8. Create: Efficiency #3464209
      Value: 92 %
    9. Create: Control #3464210
      Value: Electronic
    10. Create: Installation #3464211
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3464212
      Value: Stainless steel
    12. Create: Mains voltage #3464213
      Value: Single-phase
    13. Create: Built-in circulation pump #3464214
      Value: There is
    14. Create: Built-in expansion tank #3464215
      Value: There is
    15. Create: Equipment #3464216
      Value: Display
    16. Create: Fuel #3464217
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3464218
      Value: 1.86 cu. m/hour
    18. Create: LPG consumption #3464219
      Value: 1.43 kg/h
    19. Create: Nominal pressure of natural gas #3464220
      Value: 10 - 25 mbar
    20. Create: Permissible LPG pressure #3464221
      Value: 28 mbar
    21. Create: Heat carrier temperature #3464222
      Value: 40 - 80 °С
    22. Create: Temperature in the DHW circuit #3464223
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3464224
      Value: 13.8 l/min
    24. Create: Hot water capacity at t 40°C #3464225
      Value: 8.6 l/min
    25. Create: Max. water pressure in the DHW circuit #3464226
      Value: 8 bar
    26. Create: Max. water pressure in the heating circuit #3464227
      Value: 3 bar
    27. Create: Functions #3464228
      Value: Frost protection, thermometer, manometer
    28. Create: Protection #3464229
      Value: Gas control, safety valve, air vent
    29. Create: Gas connection #3464230
      Value: 1/2"
    30. Create: Heating circuit connection #3464231
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3464232
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3464233
      Value: 60/100 mm
    33. Create: Connection of a separate chimney diameter 80 mm #3464234
      Value: Yes
    34. Create: Dimensions WxHxD #3464235
      Value: 440x695x265 mm
    35. Create: Weight #3464236
      Value: 28 kg
    36. Create: Additional Information #3464237
      Value: Smart remote control with voice assistant option
    37. Create: Image #6333377
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1327470495532401926/orig
    38. Create: Preview image #6333378
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1327470495532401926/orig
  3. Donny Darko 30 April 2023 08:40:13
    Name: Gas boiler Navien PRIME 16K; Catalog: Heating boilers