Change history for item: Gas boiler Navien DELUXE 35K

  1. Donny Darko 08 July 2023 11:48:01
    1. Create: Description #3464109
      Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3464110
      Value: Gas, convection
    3. Create: Burner #3464111
      Value: Gas
    4. Create: Number of circuits #3464112
      Value: Double-circuit
    5. Create: Thermal power #3464113
      Value: 14 - 35 kW
    6. Create: The combustion chamber #3464114
      Value: Closed
    7. Create: Heated area #3464115
      Value: 350 sq.m
    8. Create: Efficiency #3464116
      Value: 91.5 %
    9. Create: Control #3464117
      Value: Electronic
    10. Create: Installation #3464118
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3464119
      Value: Stainless steel
    12. Create: Mains voltage #3464120
      Value: Single-phase
    13. Create: Peculiarities #3464121
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, thermometer
    14. Create: Equipment #3464122
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3464123
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3464124
      Value: 3.77 cu. m/hour
    17. Create: LPG consumption #3464125
      Value: 3.14 kg/h
    18. Create: Nominal pressure of natural gas #3464126
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3464127
      Value: 28 mbar
    20. Create: Heat carrier temperature #3464128
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3464129
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3464130
      Value: 20.1 l/min
    23. Create: Max. water pressure in the DHW circuit #3464131
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3464132
      Value: 3 bar
    25. Create: Gas connection #3464133
      Value: 3/4"
    26. Create: Heating circuit connection #3464134
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3464135
      Value: 1/2"
    28. Create: Dimensions WxHxD #3464136
      Value: 440x695x265 mm
    29. Create: Weight #3464137
      Value: 30 kg
    30. Create: Additional Information #3464138
      Value: Pipe diameter of the smoke exhaust system 75/70
    31. Create: Image #6333363
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5898501274555814281/orig
    32. Create: Image #6333364
      URL: https://avatars.mds.yandex.net/get-mpic/1750207/img_id7834510129450552898.jpeg/orig
    33. Create: Image #6333365
      URL: https://avatars.mds.yandex.net/get-mpic/1884605/img_id6652207564601003763.jpeg/orig
    34. Create: Preview image #6333366
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id5898501274555814281/orig
  2. Donny Darko 30 April 2023 08:40:12
    Name: Gas boiler Navien DELUXE 35K; Catalog: Heating boilers