- Donny Darko 08 July 2023 11:47:39
-
Create:
Peculiarities #3464048
Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
- Donny Darko 08 July 2023 11:47:16
-
Create:
Description #3463924
Value: Boiler type: gas, number of circuits: two-circuit, max. heat output: 40 kW, heated area: 400 m², location: wall-mounted, electrical network type: single-phase, combustion chamber type: closed,
-
Create:
Type of heating boiler #3463925
Value: Gas, convection
-
Create:
Burner #3463926
Value: Gas
-
Create:
Number of circuits #3463927
Value: Double-circuit
-
Create:
Thermal power #3463928
Value: 14 - 40 kW
-
Create:
The combustion chamber #3463929
Value: Closed
-
Create:
Heated area #3463930
Value: 400 sq.m
-
Create:
Efficiency #3463931
Value: 91.5 %
-
Create:
Control #3463932
Value: Electronic
-
Create:
Installation #3463933
Value: Wall-mounted
-
Create:
Primary heat exchanger material #3463934
Value: Stainless steel
-
Create:
Mains voltage #3463935
Value: Single-phase
-
Create:
Built-in circulation pump #3463936
Value: There is
-
Create:
Built-in expansion tank #3463937
Value: There is
-
Create:
Equipment #3463938
Value: Display, room thermostat, remote control
-
Create:
Fuel #3463939
Value: Natural gas, liquefied gas
-
Create:
Natural gas consumption #3463940
Value: 4.39 cu. m/hour
-
Create:
LPG consumption #3463941
Value: 3.58 kg/hour
-
Create:
Nominal pressure of natural gas #3463942
Value: 10 - 25 mbar
-
Create:
Permissible LPG pressure #3463943
Value: 28 mbar
-
Create:
Heat carrier temperature #3463944
Value: 40 - 80 °С
-
Create:
Temperature in the DHW circuit #3463945
Value: 30 - 60 °С
-
Create:
Hot water capacity at t 25°C #3463946
Value: 22.9 l/min
-
Create:
Hot water capacity at t 40°C #3463947
Value: 14.3 l/min
-
Create:
Max. water pressure in the DHW circuit #3463948
Value: 8 bar
-
Create:
Max. water pressure in the heating circuit #3463949
Value: 3 bar
-
Create:
Functions #3463950
Value: Frost protection, thermometer, manometer
-
Create:
Protection #3463951
Value: Gas control
-
Create:
Gas connection #3463952
Value: 3/4"
-
Create:
Heating circuit connection #3463953
Value: 3/4"
-
Create:
Branch pipe for connecting the DHW circuit #3463954
Value: 1/2"
-
Create:
Connection of a separate chimney diameter 80 mm #3463955
Value: Yes
-
Create:
Dimensions WxHxD #3463956
Value: 440x695x265 mm
-
Create:
Weight #3463957
Value: 30 kg
-
Create:
Image #6333337
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1985179593619609636/orig
-
Create:
Preview image #6333338
URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id1985179593619609636/orig
- Donny Darko 30 April 2023 08:40:10
Name: Gas boiler Navien ACE 40KN 40 kW double-circuit; Catalog: Heating boilers