Change history for item: Gas boiler Navien ACE 24KN 24 kW double-circuit

  1. Donny Darko 08 July 2023 11:47:04
    1. Create: Description #3463831
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3463832
      Value: Gas, convection
    3. Create: Burner #3463833
      Value: Gas
    4. Create: Number of circuits #3463834
      Value: Double-circuit
    5. Create: Thermal power #3463835
      Value: 9 - 24 kW
    6. Create: The combustion chamber #3463836
      Value: Closed
    7. Create: Heated area #3463837
      Value: 240 sq.m
    8. Create: Efficiency #3463838
      Value: 90.5 %
    9. Create: Control #3463839
      Value: Electronic
    10. Create: Installation #3463840
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3463841
      Value: Stainless steel
    12. Create: Mains voltage #3463842
      Value: Single-phase
    13. Create: Peculiarities #3463843
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, thermometer
    14. Create: Equipment #3463844
      Value: Display, room thermostat, remote control
    15. Create: Fuel #3463845
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3463846
      Value: 2.58 cu. m/hour
    17. Create: LPG consumption #3463847
      Value: 2.15 kg/hour
    18. Create: Nominal pressure of natural gas #3463848
      Value: 10 - 25 mbar
    19. Create: Permissible LPG pressure #3463849
      Value: 28 mbar
    20. Create: Heat carrier temperature #3463850
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3463851
      Value: 30 - 60 °С
    22. Create: Hot water capacity at t 25°C #3463852
      Value: 13.8 l/min
    23. Create: Hot water capacity at t 40°C #3463853
      Value: 8.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3463854
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3463855
      Value: 3 bar
    26. Create: Gas connection #3463856
      Value: 1/2"
    27. Create: Heating circuit connection #3463857
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3463858
      Value: 1/2"
    29. Create: Connection of a separate chimney diameter 80 mm #3463859
      Value: Yes
    30. Create: Dimensions WxHxD #3463860
      Value: 440x695x265 mm
    31. Create: Weight #3463861
      Value: 28 kg
    32. Create: Image #6333331
      URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id2403514207843591789/orig
    33. Create: Preview image #6333332
      URL: https://avatars.mds.yandex.net/get-mpic/1522540/img_id2403514207843591789/orig
  2. Donny Darko 30 April 2023 08:40:10
    Name: Gas boiler Navien ACE 24KN 24 kW double-circuit; Catalog: Heating boilers