Change history for item: Gas MORA-TOP Helios 18 KT 18.6 kW double-circuit

  1. Donny Darko 08 July 2023 11:44:47
    1. Create: Description #3463247
      Value: Type of heating boiler: gas, max. thermal power: 18.60 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, combustion chamber type: closed, power type: single-phase, control: electric
    2. Create: Type of heating boiler #3463248
      Value: Gas, convection
    3. Create: Burner #3463249
      Value: Gas
    4. Create: Number of circuits #3463250
      Value: Double-circuit
    5. Create: Thermal power #3463251
      Value: 7.50 - 18.60 kW
    6. Create: Thermal load #3463252
      Value: 9.20 - 20.70 kW
    7. Create: The combustion chamber #3463253
      Value: Closed
    8. Create: Efficiency #3463254
      Value: 93 %
    9. Create: Control #3463255
      Value: Electronic
    10. Create: Installation #3463256
      Value: Wall-mounted
    11. Create: Mains voltage #3463257
      Value: Single-phase
    12. Create: Peculiarities #3463258
      Value: Built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3463259
      Value: 8 l
    14. Create: Equipment #3463260
      Value: Display
    15. Create: Fuel #3463261
      Value: Natural gas
    16. Create: Natural gas consumption #3463262
      Value: 2.16 cu. m/hour
    17. Create: Nominal pressure of natural gas #3463263
      Value: 20 mbar
    18. Create: Heat carrier temperature #3463264
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3463265
      Value: 30 - 65 °С
    20. Create: Hot water capacity at t 25°C #3463266
      Value: 10.5 l/min
    21. Create: Hot water capacity at t 30°C #3463267
      Value: 8.7 l/min
    22. Create: Hot water capacity at t 35°C #3463268
      Value: 7.5 l/min
    23. Create: Max. water pressure in the DHW circuit #3463269
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3463270
      Value: 3 bar
    25. Create: Gas connection #3463271
      Value: 3/4"
    26. Create: Heating circuit connection #3463272
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3463273
      Value: 1/2"
    28. Create: Connection of a separate chimney diameter 80 mm #3463274
      Value: Yes
    29. Create: Dimensions WxHxD #3463275
      Value: 400x750x340 mm
    30. Create: Weight #3463276
      Value: 28.5 kg
    31. Create: Additional Information #3463277
      Value: Coaxial chimney diameter: 60/110
    32. Create: Image #6333208
      URL: https://avatars.mds.yandex.net/get-mpic/1808939/img_id6350878414859146792.jpeg/orig
    33. Create: Image #6333209
      URL: https://avatars.mds.yandex.net/get-mpic/5131700/img_id8782616520271294145.jpeg/orig
    34. Create: Preview image #6333210
      URL: https://avatars.mds.yandex.net/get-mpic/1808939/img_id6350878414859146792.jpeg/orig
  2. Donny Darko 30 April 2023 08:40:02
    Name: Gas MORA-TOP Helios 18 KT 18.6 kW double-circuit; Catalog: Heating boilers