Change history for item: Gas MORA-TOP Sirius PK35KT 30.85 kW double-circuit

  1. Donny Darko 08 July 2023 11:42:56
    1. Create: Description #3462596
      Value: Type of heating boiler: gas, max. thermal power: 30.85 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
    2. Create: Type of heating boiler #3462597
      Value: Gas, convection
    3. Create: Burner #3462598
      Value: Gas
    4. Create: Number of circuits #3462599
      Value: Double-circuit
    5. Create: Thermal power #3462600
      Value: 7.70 - 30.85 kW
    6. Create: Thermal load #3462601
      Value: 9 - 33.34 kW
    7. Create: The combustion chamber #3462602
      Value: Closed
    8. Create: Efficiency #3462603
      Value: 92.55 %
    9. Create: Control #3462604
      Value: Electronic
    10. Create: Installation #3462605
      Value: Wall-mounted
    11. Create: Mains voltage #3462606
      Value: Single-phase
    12. Create: Peculiarities #3462607
      Value: Air vent, built-in expansion tank, built-in circulation pump, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3462608
      Value: 7 l
    14. Create: Equipment #3462609
      Value: Display
    15. Create: Fuel #3462610
      Value: Natural gas
    16. Create: Natural gas consumption #3462611
      Value: 3.5 cu. m/hour
    17. Create: Nominal pressure of natural gas #3462612
      Value: 13 mbar
    18. Create: Heat carrier temperature #3462613
      Value: 20 - 80 °C
    19. Create: Temperature in the DHW circuit #3462614
      Value: 30 - 60 °С
    20. Create: Hot water capacity at t 25°C #3462615
      Value: 17.9 l/min
    21. Create: Hot water capacity at t 30°C #3462616
      Value: 15.1 l/min
    22. Create: Hot water capacity at t 35°C #3462617
      Value: 12.5 l/min
    23. Create: Max. water pressure in the DHW circuit #3462618
      Value: 6 bar
    24. Create: Max. water pressure in the heating circuit #3462619
      Value: 3 bar
    25. Create: Gas connection #3462620
      Value: 3/4"
    26. Create: Heating circuit connection #3462621
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3462622
      Value: 1/2"
    28. Create: Coaxial chimney diameter #3462623
      Value: 60/100 mm
    29. Create: Dimensions WxHxD #3462624
      Value: 600x789x396 mm
    30. Create: Weight #3462625
      Value: 44 kg
    31. Create: Image #6333146
      URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id7957833115344329135/orig
    32. Create: Preview image #6333147
      URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id7957833115344329135/orig
  2. Donny Darko 30 April 2023 08:39:54
    Name: Gas MORA-TOP Sirius PK35KT 30.85 kW double-circuit; Catalog: Heating boilers