Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 11:38:00
Create:
Description #3461234
Value: Type of heating boiler: gas, max. thermal power: 31.30 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: open, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3461235
Value: Gas
Create:
Burner #3461236
Value: Gas
Create:
Number of circuits #3461237
Value: Double-circuit
Create:
Thermal power #3461238
Value: 9.70 - 31.30 kW
Create:
Thermal load #3461239
Value: 11.50 - 34.40 kW
Create:
The combustion chamber #3461240
Value: Open
Create:
Efficiency #3461241
Value: 91 %
Create:
Control #3461242
Value: Electronic
Create:
Installation #3461243
Value: Wall-mounted
Create:
Primary heat exchanger material #3461244
Value: Copper
Create:
Secondary heat exchanger material #3461245
Value: Stainless steel
Create:
Mains voltage #3461246
Value: Single-phase
Create:
Peculiarities #3461247
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3461248
Value: 10 l
Create:
Equipment #3461249
Value: Display
Create:
Fuel #3461250
Value: Natural gas
Create:
Natural gas consumption #3461251
Value: 3.64 cu. m/hour
Create:
LPG consumption #3461252
Value: 2.69 kg/h
Create:
Nominal pressure of natural gas #3461253
Value: 20 mbar
Create:
Permissible LPG pressure #3461254
Value: 37 mbar
Create:
Heat carrier temperature #3461255
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3461256
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3461257
Value: 17.9 l/min
Create:
Hot water capacity at t 30°C #3461258
Value: 14.9 l/min
Create:
Max. water pressure in the DHW circuit #3461259
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3461260
Value: 3 bar
Create:
Gas connection #3461261
Value: 3/4"
Create:
Heating circuit connection #3461262
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3461263
Value: 1/2"
Create:
Dimensions WxHxD #3461264
Value: 400x700x330mm
Create:
Weight #3461265
Value: 30 kg
Create:
Image #6332955
URL: https://avatars.mds.yandex.net/get-mpic/1525999/img_id4598847655135827050.jpeg/orig
Create:
Image #6332956
URL: https://avatars.mds.yandex.net/get-mpic/5228636/img_id7409886522396699429.jpeg/orig
Create:
Image #6332957
URL: https://avatars.mds.yandex.net/get-mpic/397397/img_id2358322680093866502.jpeg/orig
Create:
Preview image #6332958
URL: https://avatars.mds.yandex.net/get-mpic/1525999/img_id4598847655135827050.jpeg/orig
Donny Darko 30 April 2023 08:39:36
Name: Gas Lamborghini Calor FL D 32 C 31.3 kW bypass; Catalog: Heating boilers