Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 11:37:53
Create:
Description #3461168
Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3461169
Value: Gas
Create:
Burner #3461170
Value: Gas
Create:
Number of circuits #3461171
Value: Double-circuit
Create:
Thermal power #3461172
Value: 7.20 - 24 kW
Create:
Thermal load #3461173
Value: 8.30 - 25.80 kW
Create:
The combustion chamber #3461174
Value: Closed
Create:
Efficiency #3461175
Value: 93 %
Create:
Control #3461176
Value: Electronic
Create:
Installation #3461177
Value: Wall-mounted
Create:
Primary heat exchanger material #3461178
Value: Copper
Create:
Mains voltage #3461179
Value: Single-phase
Create:
Peculiarities #3461180
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
Create:
Expansion tank volume #3461181
Value: 8 l
Create:
Equipment #3461182
Value: Display
Create:
Fuel #3461183
Value: Natural gas
Create:
Natural gas consumption #3461184
Value: 2.73 cu. m/hour
Create:
LPG consumption #3461185
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3461186
Value: 20 mbar
Create:
Permissible LPG pressure #3461187
Value: 37 mbar
Create:
Heat carrier temperature #3461188
Value: 30 - 90 °С
Create:
Temperature in the DHW circuit #3461189
Value: 40 - 55 °С
Create:
Hot water capacity at t 25°C #3461190
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3461191
Value: 11.4 l/min
Create:
Max. water pressure in the DHW circuit #3461192
Value: 9 bar
Create:
Max. water pressure in the heating circuit #3461193
Value: 3 bar
Create:
Gas connection #3461194
Value: 3/4"
Create:
Heating circuit connection #3461195
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3461196
Value: 1/2"
Create:
Coaxial chimney diameter #3461197
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3461198
Value: Yes
Create:
Dimensions WxHxD #3461199
Value: 400x700x330mm
Create:
Weight #3461200
Value: 32 kg
Create:
Image #6332946
URL: https://avatars.mds.yandex.net/get-mpic/1589815/img_id4272965963860797130.jpeg/orig
Create:
Image #6332947
URL: https://avatars.mds.yandex.net/get-mpic/5228636/img_id7409886522396699429.jpeg/orig
Create:
Image #6332948
URL: https://avatars.mds.yandex.net/get-mpic/4101287/img_id8423988309778176979.jpeg/orig
Create: