Change history for item: Gas Lamborghini Calor XILO D 20 MCS W TOP 22.75 kW bypass

  1. Donny Darko 08 July 2023 11:36:27
    1. Create: Description #3460652
      Value: Type of heating boiler: gas, max. heating power: 22.75 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3460653
      Value: Gas, convection
    3. Create: Burner #3460654
      Value: Gas
    4. Create: Number of circuits #3460655
      Value: Double-circuit
    5. Create: Thermal power #3460656
      Value: 8.31 - 22.75 kW
    6. Create: Thermal load #3460657
      Value: 10 - 25 kW
    7. Create: The combustion chamber #3460658
      Value: Closed
    8. Create: Efficiency #3460659
      Value: 91.3 %
    9. Create: Control #3460660
      Value: Electronic
    10. Create: Installation #3460661
      Value: Wall-mounted
    11. Create: Secondary heat exchanger material #3460662
      Value: Copper
    12. Create: Mains voltage #3460663
      Value: Single-phase
    13. Create: Peculiarities #3460664
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3460665
      Value: 8 l
    15. Create: Fuel #3460666
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3460667
      Value: 2.52 cu. m/hour
    17. Create: Nominal pressure of natural gas #3460668
      Value: 5 - 20 mbar
    18. Create: Permissible LPG pressure #3460669
      Value: 37 mbar
    19. Create: Heat carrier temperature #3460670
      Value: 30 - 80 °С
    20. Create: Hot water capacity at t 30°C #3460671
      Value: 11 l/min
    21. Create: Max. water pressure in the DHW circuit #3460672
      Value: 8 bar
    22. Create: Max. water pressure in the heating circuit #3460673
      Value: 3 bar
    23. Create: Gas connection #3460674
      Value: 3/4"
    24. Create: Heating circuit connection #3460675
      Value: 1/2"
    25. Create: Branch pipe for connecting the DHW circuit #3460676
      Value: 3/4"
    26. Create: Coaxial chimney diameter #3460677
      Value: 60/100 mm
    27. Create: Dimensions WxHxD #3460678
      Value: 515x845x390 mm
    28. Create: Weight #3460679
      Value: 41 kg
    29. Create: Image #6332864
      URL: https://avatars.mds.yandex.net/get-mpic/1911047/img_id8916262258307053979/orig
    30. Create: Preview image #6332865
      URL: https://avatars.mds.yandex.net/get-mpic/1911047/img_id8916262258307053979/orig
  2. Donny Darko 30 April 2023 08:39:29
    Name: Gas Lamborghini Calor XILO D 20 MCS W TOP 22.75 kW bypass; Catalog: Heating boilers