Change history for item: Frisquet Prestige CONDENSATION Visio 32 kW A4JL32020 double circuit

  1. Donny Darko 08 July 2023 11:31:07
    1. Create: Description #3458892
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458893
      Value: Gas, condensing
    3. Create: Burner #3458894
      Value: Gas
    4. Create: Number of circuits #3458895
      Value: Double-circuit
    5. Create: Thermal power #3458896
      Value: 23 - 32 kW
    6. Create: Max. thermal load #3458897
      Value: 33.70 kW
    7. Create: The combustion chamber #3458898
      Value: Closed
    8. Create: Efficiency #3458899
      Value: 109 %
    9. Create: Control #3458900
      Value: Electronic
    10. Create: Installation #3458901
      Value: Floor
    11. Create: Primary heat exchanger material #3458902
      Value: Copper
    12. Create: Mains voltage #3458903
      Value: Single-phase
    13. Create: Peculiarities #3458904
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458905
      Value: 18 l
    15. Create: Equipment #3458906
      Value: Display, room thermostat, remote control
    16. Create: Fuel #3458907
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458908
      Value: 3.48 cu. m/hour
    18. Create: LPG consumption #3458909
      Value: 2.55 kg/hour
    19. Create: Nominal pressure of natural gas #3458910
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458911
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458912
      Value: 20 - 90 °C
    22. Create: Temperature in the DHW circuit #3458913
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 40°C #3458914
      Value: 15.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458915
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458916
      Value: 3 bar
    26. Create: Gas connection #3458917
      Value: 3/4"
    27. Create: Heating circuit connection #3458918
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458919
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3458920
      Value: 60/100 mm and 80/125 mm
    30. Create: Dimensions WxHxD #3458921
      Value: 555x1035x570 mm
    31. Create: Weight #3458922
      Value: 74.2 kg
    32. Create: Image #6332699
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id1968950882353959301.jpeg/orig
    33. Create: Image #6332700
      URL: https://avatars.mds.yandex.net/get-mpic/3909438/img_id1745181952202366468.jpeg/orig
    34. Create: Image #6332701
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id3022331391126281529.jpeg/orig
    35. Create: Image #6332702
      URL: https://avatars.mds.yandex.net/get-mpic/4338525/img_id1578024460394598022.jpeg/orig
    36. Create: Image #6332703
      URL: https://avatars.mds.yandex.net/get-mpic/4590616/img_id844999798402548383.jpeg/orig
    37. Create: Preview image #6332704
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id1968950882353959301.jpeg/orig
  2. Donny Darko 30 April 2023 08:39:04
    Name: Frisquet Prestige CONDENSATION Visio 32 kW A4JL32020 double circuit; Catalog: Heating boilers