Change history for item: Frisquet Prestige EVOLUTION Visio 32 kW B4JL32020 double circuit

  1. Donny Darko 08 July 2023 11:31:00
    1. Create: Description #3458830
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458831
      Value: Gas, convection
    3. Create: Burner #3458832
      Value: Gas
    4. Create: Number of circuits #3458833
      Value: Double-circuit
    5. Create: Max. thermal power #3458834
      Value: 32 kW
    6. Create: Max. thermal load #3458835
      Value: 33.70 kW
    7. Create: The combustion chamber #3458836
      Value: Open
    8. Create: Efficiency #3458837
      Value: 95 %
    9. Create: Control #3458838
      Value: Electronic
    10. Create: Installation #3458839
      Value: Floor
    11. Create: Primary heat exchanger material #3458840
      Value: Copper
    12. Create: Mains voltage #3458841
      Value: Single-phase
    13. Create: Peculiarities #3458842
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458843
      Value: 18 l
    15. Create: Equipment #3458844
      Value: Display, room thermostat
    16. Create: Fuel #3458845
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458846
      Value: 3.563 cu. m/hour
    18. Create: LPG consumption #3458847
      Value: 2.616 kg/h
    19. Create: Nominal pressure of natural gas #3458848
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458849
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458850
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458851
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 40°C #3458852
      Value: 15.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458853
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458854
      Value: 3 bar
    26. Create: Gas connection #3458855
      Value: 3/4"
    27. Create: Heating circuit connection #3458856
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458857
      Value: 1/2"
    29. Create: Chimney diameter #3458858
      Value: 139 mm
    30. Create: Dimensions WxHxD #3458859
      Value: 555x1035x570 mm
    31. Create: Weight #3458860
      Value: 72.7 kg
    32. Create: Image #6332687
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id3239774970343493968.jpeg/orig
    33. Create: Image #6332688
      URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id4311884581555568631.jpeg/orig
    34. Create: Image #6332689
      URL: https://avatars.mds.yandex.net/get-mpic/4362876/img_id7199662021315824967.jpeg/orig
    35. Create: Image #6332690
      URL: https://avatars.mds.yandex.net/get-mpic/1565610/img_id8818709488367718871.jpeg/orig
    36. Create: Image #6332691
      URL: https://avatars.mds.yandex.net/get-mpic/4705079/img_id2812607118172589714.jpeg/orig
    37. Create: Preview image #6332692
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id3239774970343493968.jpeg/orig
  2. Donny Darko 30 April 2023 08:39:03
    Name: Frisquet Prestige EVOLUTION Visio 32 kW B4JL32020 double circuit; Catalog: Heating boilers