Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 08 July 2023 11:30:21
Create:
Description #3458540
Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3458541
Value: Gas, convection
Create:
Burner #3458542
Value: Gas
Create:
Number of circuits #3458543
Value: Double-circuit
Create:
Max. thermal power #3458544
Value: 25 kW
Create:
Max. thermal load #3458545
Value: 26.30 kW
Create:
The combustion chamber #3458546
Value: Closed
Create:
Efficiency #3458547
Value: 95 %
Create:
Control #3458548
Value: Electronic
Create:
Installation #3458549
Value: Floor
Create:
Primary heat exchanger material #3458550
Value: Copper
Create:
Mains voltage #3458551
Value: Single-phase
Create:
Peculiarities #3458552
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
Create:
Expansion tank volume #3458553
Value: 18 l
Create:
Equipment #3458554
Value: Display, room thermostat
Create:
Fuel #3458555
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3458556
Value: 2.78 cu. m/hour
Create:
LPG consumption #3458557
Value: 2.042 kg/h
Create:
Nominal pressure of natural gas #3458558
Value: 11 - 20 mbar
Create:
Permissible LPG pressure #3458559
Value: 37 mbar
Create:
Heat carrier temperature #3458560
Value: 20 - 85 °С
Create:
Temperature in the DHW circuit #3458561
Value: 35 - 65 °С
Create:
Hot water capacity at t 40°C #3458562
Value: 12.5 l/min
Create:
Max. water pressure in the DHW circuit #3458563
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3458564
Value: 3 bar
Create:
Gas connection #3458565
Value: 3/4"
Create:
Heating circuit connection #3458566
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3458567
Value: 1/2"
Create:
Coaxial chimney diameter #3458568
Value: 60/100 mm and 80/125 mm
Create:
Dimensions WxHxD #3458569
Value: 550x1035x570 mm
Create:
Weight #3458570
Value: 68.75 kg
Create:
Image #6332629
URL: https://avatars.mds.yandex.net/get-mpic/1865543/img_id6832326536822316343.jpeg/orig
Create:
Image #6332630
URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id3681352738975363888.jpeg/orig
Create:
Image #6332631
URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id8568252886826606663.jpeg/orig
Create:
Image #6332632
URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id4809068667324688216.jpeg/orig
Create:
Image #6332633
URL: https://avatars.mds.yandex.net/get-mpic/1554397/img_id1104840012596960445.jpeg/orig
Create:
Preview image #6332634
URL: https://avatars.mds.yandex.net/get-mpic/1865543/img_id6832326536822316343.jpeg/orig
Donny Darko 30 April 2023 08:39:00
Name: Frisquet Prestige EVOLUTION Visio 25 kW B4JN25020 double circuit; Catalog: Heating boilers