Change history for item: Frisquet Prestige EVOLUTION Visio 25 kW B4JN25020 double circuit

  1. Donny Darko 08 July 2023 11:30:21
    1. Create: Description #3458540
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458541
      Value: Gas, convection
    3. Create: Burner #3458542
      Value: Gas
    4. Create: Number of circuits #3458543
      Value: Double-circuit
    5. Create: Max. thermal power #3458544
      Value: 25 kW
    6. Create: Max. thermal load #3458545
      Value: 26.30 kW
    7. Create: The combustion chamber #3458546
      Value: Closed
    8. Create: Efficiency #3458547
      Value: 95 %
    9. Create: Control #3458548
      Value: Electronic
    10. Create: Installation #3458549
      Value: Floor
    11. Create: Primary heat exchanger material #3458550
      Value: Copper
    12. Create: Mains voltage #3458551
      Value: Single-phase
    13. Create: Peculiarities #3458552
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458553
      Value: 18 l
    15. Create: Equipment #3458554
      Value: Display, room thermostat
    16. Create: Fuel #3458555
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458556
      Value: 2.78 cu. m/hour
    18. Create: LPG consumption #3458557
      Value: 2.042 kg/h
    19. Create: Nominal pressure of natural gas #3458558
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458559
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458560
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458561
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 40°C #3458562
      Value: 12.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458563
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458564
      Value: 3 bar
    26. Create: Gas connection #3458565
      Value: 3/4"
    27. Create: Heating circuit connection #3458566
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458567
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3458568
      Value: 60/100 mm and 80/125 mm
    30. Create: Dimensions WxHxD #3458569
      Value: 550x1035x570 mm
    31. Create: Weight #3458570
      Value: 68.75 kg
    32. Create: Image #6332629
      URL: https://avatars.mds.yandex.net/get-mpic/1865543/img_id6832326536822316343.jpeg/orig
    33. Create: Image #6332630
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id3681352738975363888.jpeg/orig
    34. Create: Image #6332631
      URL: https://avatars.mds.yandex.net/get-mpic/3689399/img_id8568252886826606663.jpeg/orig
    35. Create: Image #6332632
      URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id4809068667324688216.jpeg/orig
    36. Create: Image #6332633
      URL: https://avatars.mds.yandex.net/get-mpic/1554397/img_id1104840012596960445.jpeg/orig
    37. Create: Preview image #6332634
      URL: https://avatars.mds.yandex.net/get-mpic/1865543/img_id6832326536822316343.jpeg/orig
  2. Donny Darko 30 April 2023 08:39:00
    Name: Frisquet Prestige EVOLUTION Visio 25 kW B4JN25020 double circuit; Catalog: Heating boilers