  1. Donny Darko 08 July 2023 11:30:17
    1. Create: Description #3458509
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458510
      Value: Gas, convection
    3. Create: Burner #3458511
      Value: Gas
    4. Create: Number of circuits #3458512
      Value: Double-circuit
    5. Create: Max. thermal power #3458513
      Value: 25 kW
    6. Create: Max. thermal load #3458514
      Value: 26.30 kW
    7. Create: The combustion chamber #3458515
      Value: Open
    8. Create: Efficiency #3458516
      Value: 95 %
    9. Create: Control #3458517
      Value: Electronic
    10. Create: Installation #3458518
      Value: Floor
    11. Create: Primary heat exchanger material #3458519
      Value: Copper
    12. Create: Mains voltage #3458520
      Value: Single-phase
    13. Create: Peculiarities #3458521
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458522
      Value: 18 l
    15. Create: Equipment #3458523
      Value: Display, room thermostat
    16. Create: Fuel #3458524
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458525
      Value: 2.78 cu. m/hour
    18. Create: LPG consumption #3458526
      Value: 2.042 kg/h
    19. Create: Nominal pressure of natural gas #3458527
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458528
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458529
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458530
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 40°C #3458531
      Value: 12.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458532
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458533
      Value: 3 bar
    26. Create: Gas connection #3458534
      Value: 3/4"
    27. Create: Heating circuit connection #3458535
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458536
      Value: 1/2"
    29. Create: Chimney diameter #3458537
      Value: 125 mm
    30. Create: Dimensions WxHxD #3458538
      Value: 555x1035x570 mm
    31. Create: Weight #3458539
      Value: 687 kg
    32. Create: Image #6332624
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6814091919139670772.jpeg/orig
    33. Create: Image #6332625
      URL: https://avatars.mds.yandex.net/get-mpic/4012150/img_id6499106414109951010.jpeg/orig
    34. Create: Image #6332626
      URL: https://avatars.mds.yandex.net/get-mpic/3698270/img_id4320226871632186954.jpeg/orig
    35. Create: Image #6332627
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id2046378191421983255.jpeg/orig
    36. Create: Preview image #6332628
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6814091919139670772.jpeg/orig
  2. Donny Darko 30 April 2023 08:39:00
    Name: Frisquet Prestige EVOLUTION Visio 25 kW B4JL25020 double circuit; Catalog: Heating boilers