Change history for item: Frisquet Hydromotrix EVOLUTION Visio 32 kW B4JC32020 double circuit

  1. Donny Darko 08 July 2023 11:30:13
    1. Create: Description #3458478
      Value: Type of heating boiler: gas, max. thermal power: 32 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458479
      Value: Gas, convection
    3. Create: Burner #3458480
      Value: Gas
    4. Create: Number of circuits #3458481
      Value: Double-circuit
    5. Create: Max. thermal power #3458482
      Value: 32 kW
    6. Create: Max. thermal load #3458483
      Value: 33.70 kW
    7. Create: The combustion chamber #3458484
      Value: Closed
    8. Create: Efficiency #3458485
      Value: 95 %
    9. Create: Control #3458486
      Value: Electronic
    10. Create: Installation #3458487
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3458488
      Value: Copper
    12. Create: Mains voltage #3458489
      Value: Single-phase
    13. Create: Peculiarities #3458490
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458491
      Value: 12 l
    15. Create: Equipment #3458492
      Value: Display, room thermostat
    16. Create: Fuel #3458493
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458494
      Value: 3.563 cu. m/hour
    18. Create: LPG consumption #3458495
      Value: 2.616 kg/h
    19. Create: Nominal pressure of natural gas #3458496
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458497
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458498
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458499
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 30°C #3458500
      Value: 15.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458501
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458502
      Value: 3 bar
    26. Create: Gas connection #3458503
      Value: 3/4"
    27. Create: Heating circuit connection #3458504
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458505
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3458506
      Value: 60/100 mm and 80/125 mm
    30. Create: Dimensions WxHxD #3458507
      Value: 495x915x447 mm
    31. Create: Weight #3458508
      Value: 62 kg
    32. Create: Image #6332618
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id1658935651465038447.jpeg/orig
    33. Create: Image #6332619
      URL: https://avatars.mds.yandex.net/get-mpic/1859594/img_id5051394321581783341.jpeg/orig
    34. Create: Image #6332620
      URL: https://avatars.mds.yandex.net/get-mpic/4219717/img_id2793861844565408879.jpeg/orig
    35. Create: Image #6332621
      URL: https://avatars.mds.yandex.net/get-mpic/4736439/img_id5296382132584761159.jpeg/orig
    36. Create: Image #6332622
      URL: https://avatars.mds.yandex.net/get-mpic/4762868/img_id7160556147758998034.jpeg/orig
    37. Create: Preview image #6332623
      URL: https://avatars.mds.yandex.net/get-mpic/4462738/img_id1658935651465038447.jpeg/orig
  2. Donny Darko 30 April 2023 08:39:00