Change history for item: Frisquet Hydroconfort EVOLUTION Visio 25 kW B4JJ25510 double circuit

  1. Donny Darko 08 July 2023 11:30:05
    1. Create: Description #3458413
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458414
      Value: Gas, convection
    3. Create: Burner #3458415
      Value: Gas
    4. Create: Number of circuits #3458416
      Value: Double-circuit
    5. Create: Max. thermal power #3458417
      Value: 25 kW
    6. Create: Max. thermal load #3458418
      Value: 26.30 kW
    7. Create: The combustion chamber #3458419
      Value: Closed
    8. Create: Efficiency #3458420
      Value: 95 %
    9. Create: Control #3458421
      Value: Electronic
    10. Create: Installation #3458422
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3458423
      Value: Copper
    12. Create: Mains voltage #3458424
      Value: Single-phase
    13. Create: Peculiarities #3458425
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: The volume of the built-in boiler #3458426
      Value: 80 l
    15. Create: Expansion tank volume #3458427
      Value: 12 l
    16. Create: Equipment #3458428
      Value: Built-in boiler, display, room thermostat
    17. Create: Fuel #3458429
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3458430
      Value: 2.78 cu. m/hour
    19. Create: LPG consumption #3458431
      Value: 2.042 kg/h
    20. Create: Nominal pressure of natural gas #3458432
      Value: 11 - 20 mbar
    21. Create: Permissible LPG pressure #3458433
      Value: 37 mbar
    22. Create: Heat carrier temperature #3458434
      Value: 20 - 85 °С
    23. Create: Temperature in the DHW circuit #3458435
      Value: 35 - 65 °С
    24. Create: Hot water capacity at t 40°C #3458436
      Value: 20 l/min
    25. Create: Max. water pressure in the DHW circuit #3458437
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3458438
      Value: 3 bar
    27. Create: Gas connection #3458439
      Value: 3/4"
    28. Create: Heating circuit connection #3458440
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3458441
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3458442
      Value: 60/100 mm and 80/125 mm
    31. Create: Dimensions WxHxD #3458443
      Value: 785x953x472 mm
    32. Create: Weight #3458444
      Value: 79 kg
    33. Create: Image #6332608
      URL: https://avatars.mds.yandex.net/get-mpic/1865723/img_id2390247476812745950.jpeg/orig
    34. Create: Image #6332609
      URL: https://avatars.mds.yandex.net/get-mpic/4219828/img_id4305268796380159717.jpeg/orig
    35. Create: Image #6332610
      URL: https://avatars.mds.yandex.net/get-mpic/4383514/img_id8627412219558830608.jpeg/orig
    36. Create: Image #6332611
      URL: https://avatars.mds.yandex.net/get-mpic/4303817/img_id7914209681979107020.jpeg/orig
    37. Create: Preview image #6332612
      URL: https://avatars.mds.yandex.net/get-mpic/1865723/img_id2390247476812745950.jpeg/orig
  2. Donny Darko 30 April 2023 08:38:59
    Name: Frisquet Hydroconfort EVOLUTION Visio 25 kW B4JJ25510 double circuit; Catalog: Heating boilers