Change history for item: Frisquet Hydromotrix EVOLUTION Visio 45 kW B4JB45020 double circuit

  1. Donny Darko 08 July 2023 11:30:01
    1. Create: Description #3458382
      Value: Type of heating boiler: gas, max. thermal power: 45 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458383
      Value: Gas, convection
    3. Create: Burner #3458384
      Value: Gas
    4. Create: Number of circuits #3458385
      Value: Double-circuit
    5. Create: Max. thermal power #3458386
      Value: 45 kW
    6. Create: Max. thermal load #3458387
      Value: 47 kW
    7. Create: The combustion chamber #3458388
      Value: Open
    8. Create: Efficiency #3458389
      Value: 95 %
    9. Create: Control #3458390
      Value: Electronic
    10. Create: Installation #3458391
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3458392
      Value: Copper
    12. Create: Mains voltage #3458393
      Value: Single-phase
    13. Create: Peculiarities #3458394
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458395
      Value: 18 l
    15. Create: Equipment #3458396
      Value: Display, room thermostat
    16. Create: Fuel #3458397
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458398
      Value: 5.022 cu. m/hour
    18. Create: LPG consumption #3458399
      Value: 3.687 kg/hour
    19. Create: Nominal pressure of natural gas #3458400
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458401
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458402
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458403
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 30°C #3458404
      Value: 19 l/min
    24. Create: Max. water pressure in the DHW circuit #3458405
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458406
      Value: 3 bar
    26. Create: Gas connection #3458407
      Value: 3/4"
    27. Create: Heating circuit connection #3458408
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458409
      Value: 1/2"
    29. Create: Chimney diameter #3458410
      Value: 180 mm
    30. Create: Dimensions WxHxD #3458411
      Value: 710x967x480 mm
    31. Create: Weight #3458412
      Value: 91.5 kg
    32. Create: Image #6332601
      URL: https://avatars.mds.yandex.net/get-mpic/4561793/img_id4102710869128921158.jpeg/orig
    33. Create: Image #6332602
      URL: https://avatars.mds.yandex.net/get-mpic/1862611/img_id7833857809249675559.jpeg/orig
    34. Create: Image #6332603
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id4472337477663110440.jpeg/orig
    35. Create: Image #6332604
      URL: https://avatars.mds.yandex.net/get-mpic/3694390/img_id5517125846985303402.jpeg/orig
    36. Create: Image #6332605
      URL: https://avatars.mds.yandex.net/get-mpic/4947485/img_id9034696783756712114.jpeg/orig
    37. Create: Image #6332606
      URL: https://avatars.mds.yandex.net/get-mpic/3923571/img_id5301049379130472337.jpeg/orig
    38. Create: Preview image #6332607
      URL: https://avatars.mds.yandex.net/get-mpic/4561793/img_id4102710869128921158.jpeg/orig
  2. Donny Darko 30 April 2023 08:38:59
    Name: Frisquet Hydromotrix EVOLUTION Visio 45 kW B4JB45020 double circuit; Catalog: Heating boilers