Change history for item: Frisquet Hydromotrix EVOLUTION Visio 25 kW B4JC25020 dual circuit

  1. Donny Darko 08 July 2023 11:29:25
    1. Create: Description #3458320
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458321
      Value: Gas, convection
    3. Create: Burner #3458322
      Value: Gas
    4. Create: Number of circuits #3458323
      Value: Double-circuit
    5. Create: Max. thermal power #3458324
      Value: 25 kW
    6. Create: Max. thermal load #3458325
      Value: 26.30 kW
    7. Create: The combustion chamber #3458326
      Value: Closed
    8. Create: Efficiency #3458327
      Value: 95.13 %
    9. Create: Control #3458328
      Value: Electronic
    10. Create: Installation #3458329
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3458330
      Value: Copper
    12. Create: Mains voltage #3458331
      Value: Single-phase
    13. Create: Peculiarities #3458332
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458333
      Value: 11 l
    15. Create: Equipment #3458334
      Value: Display, room thermostat
    16. Create: Fuel #3458335
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458336
      Value: 2.78 cu. m/hour
    18. Create: LPG consumption #3458337
      Value: 2.042 kg/h
    19. Create: Nominal pressure of natural gas #3458338
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458339
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458340
      Value: 20 - 85 °С
    22. Create: Temperature in the DHW circuit #3458341
      Value: 35 - 65 °С
    23. Create: Hot water capacity at t 30°C #3458342
      Value: 12.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3458343
      Value: 10 bar
    25. Create: Max. water pressure in the heating circuit #3458344
      Value: 3 bar
    26. Create: Gas connection #3458345
      Value: 3/4"
    27. Create: Heating circuit connection #3458346
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3458347
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3458348
      Value: 60/100 mm and 80/125 mm
    30. Create: Dimensions WxHxD #3458349
      Value: 495x795x437 mm
    31. Create: Weight #3458350
      Value: 56 kg
    32. Create: Image #6332589
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id3022066310333338236.jpeg/orig
    33. Create: Image #6332590
      URL: https://avatars.mds.yandex.net/get-mpic/1767151/img_id2148454734270007017.jpeg/orig
    34. Create: Image #6332591
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id6823680220011891500.jpeg/orig
    35. Create: Image #6332592
      URL: https://avatars.mds.yandex.net/get-mpic/4412310/img_id7311663510246258041.jpeg/orig
    36. Create: Image #6332593
      URL: https://avatars.mds.yandex.net/get-mpic/4947485/img_id2988160262543441708.jpeg/orig
    37. Create: Preview image #6332594
      URL: https://avatars.mds.yandex.net/get-mpic/4250892/img_id3022066310333338236.jpeg/orig
  2. Donny Darko 30 April 2023 08:38:58
    Name: Frisquet Hydromotrix EVOLUTION Visio 25 kW B4JC25020 dual circuit; Catalog: Heating boilers