Change history for item: Frisquet Hydromotrix EVOLUTION Visio 25 kW B4JA25050 single circuit

  1. Donny Darko 08 July 2023 11:29:21
    1. Create: Description #3458293
      Value: Type of heating boiler: gas, max. thermal power: 25 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3458294
      Value: Gas, convection
    3. Create: Burner #3458295
      Value: Gas
    4. Create: Number of circuits #3458296
      Value: Single-loop
    5. Create: Max. thermal power #3458297
      Value: 25 kW
    6. Create: Max. thermal load #3458298
      Value: 26.30 kW
    7. Create: The combustion chamber #3458299
      Value: Open
    8. Create: Efficiency #3458300
      Value: 95 %
    9. Create: Control #3458301
      Value: Electronic
    10. Create: Installation #3458302
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3458303
      Value: Copper
    12. Create: Mains voltage #3458304
      Value: Single-phase
    13. Create: Peculiarities #3458305
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3458306
      Value: 11 l
    15. Create: Equipment #3458307
      Value: Display, room thermostat
    16. Create: Fuel #3458308
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3458309
      Value: 2.78 cu. m/hour
    18. Create: LPG consumption #3458310
      Value: 2.042 kg/h
    19. Create: Nominal pressure of natural gas #3458311
      Value: 11 - 20 mbar
    20. Create: Permissible LPG pressure #3458312
      Value: 37 mbar
    21. Create: Heat carrier temperature #3458313
      Value: 20 - 85 °С
    22. Create: Max. water pressure in the heating circuit #3458314
      Value: 3 bar
    23. Create: Gas connection #3458315
      Value: 3/4"
    24. Create: Heating circuit connection #3458316
      Value: 3/4"
    25. Create: Chimney diameter #3458317
      Value: 125 mm
    26. Create: Dimensions WxHxD #3458318
      Value: 495x795x437 mm
    27. Create: Weight #3458319
      Value: 50 kg
    28. Create: Image #6332583
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id2327899488406532884.jpeg/orig
    29. Create: Image #6332584
      URL: https://avatars.mds.yandex.net/get-mpic/1926869/img_id4752784106928806039.jpeg/orig
    30. Create: Image #6332585
      URL: https://avatars.mds.yandex.net/get-mpic/4728959/img_id6336424079835140293.jpeg/orig
    31. Create: Image #6332586
      URL: https://avatars.mds.yandex.net/get-mpic/4289990/img_id8208021783852139652.jpeg/orig
    32. Create: Image #6332587
      URL: https://avatars.mds.yandex.net/get-mpic/4466970/img_id5364241320588162017.jpeg/orig
    33. Create: Preview image #6332588
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id2327899488406532884.jpeg/orig
  2. Donny Darko 30 April 2023 08:38:58
    Name: Frisquet Hydromotrix EVOLUTION Visio 25 kW B4JA25050 single circuit; Catalog: Heating boilers