    1. Create: Description #3453613
      Value: Type of heating boiler: gas, max. heating power: 32.40 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3453614
      Value: Gas, convection
    3. Create: Burner #3453615
      Value: Gas
    4. Create: Number of circuits #3453616
      Value: Double-circuit
    5. Create: Thermal power #3453617
      Value: 11.70 - 32.40 kW
    6. Create: Thermal load #3453618
      Value: 13.60 - 34.50 kW
    7. Create: The combustion chamber #3453619
      Value: Closed
    8. Create: Efficiency #3453620
      Value: 94 %
    9. Create: Control #3453621
      Value: Electronic
    10. Create: Installation #3453622
      Value: Wall-mounted
    11. Create: Mains voltage #3453623
      Value: Single-phase
    12. Create: Peculiarities #3453624
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3453625
      Value: 10 l
    14. Create: Equipment #3453626
      Value: Display
    15. Create: Fuel #3453627
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3453628
      Value: 3.65 cu. m/hour
    17. Create: LPG consumption #3453629
      Value: 1.44 kg/h
    18. Create: Nominal pressure of natural gas #3453630
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3453631
      Value: 35 mbar
    20. Create: Heat carrier temperature #3453632
      Value: 35 - 80 °С
    21. Create: Temperature in the DHW circuit #3453633
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3453634
      Value: 18.6 l/min
    23. Create: Hot water capacity at t 30°C #3453635
      Value: 15.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3453636
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3453637
      Value: 3 bar
    26. Create: Gas connection #3453638
      Value: 1/2"
    27. Create: Heating circuit connection #3453639
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3453640
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3453641
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3453642
      Value: Yes
    31. Create: Dimensions WxHxD #3453643
      Value: 400x727x300mm
    32. Create: Weight #3453644
      Value: 358 kg
    33. Create: Image #6332040
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id4919522593500554317.jpeg/orig
    34. Create: Image #6332041
      URL: https://avatars.mds.yandex.net/get-mpic/5221857/img_id8027279955600389876.jpeg/orig
    35. Create: Image #6332042
      URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id4145799055867067172.jpeg/orig
    36. Create: Preview image #6332043
      URL: https://avatars.mds.yandex.net/get-mpic/4355034/img_id4919522593500554317.jpeg/orig
  2. Donny Darko 30 April 2023 08:37:55
    Name: Gas boiler Baltur Tesis 32 32.4 kW double-circuit; Catalog: Heating boilers