Change history for item: Gas boiler Baltur Tesis 28 28.2 kW double-circuit

  1. Donny Darko 08 July 2023 11:11:23
    1. Create: Description #3453581
      Value: Type of heating boiler: gas, max. thermal power: 28.20 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3453582
      Value: Gas, convection
    3. Create: Burner #3453583
      Value: Gas
    4. Create: Number of circuits #3453584
      Value: Double-circuit
    5. Create: Thermal power #3453585
      Value: 10.20 - 28.20 kW
    6. Create: Thermal load #3453586
      Value: 12 - 30 kW
    7. Create: The combustion chamber #3453587
      Value: Closed
    8. Create: Efficiency #3453588
      Value: 94 %
    9. Create: Control #3453589
      Value: Electronic
    10. Create: Installation #3453590
      Value: Wall-mounted
    11. Create: Mains voltage #3453591
      Value: Single-phase
    12. Create: Peculiarities #3453592
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3453593
      Value: 8 l
    14. Create: Equipment #3453594
      Value: Display
    15. Create: Fuel #3453595
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3453596
      Value: 3.17 cu. m/hour
    17. Create: LPG consumption #3453597
      Value: 1.27 kg/hour
    18. Create: Nominal pressure of natural gas #3453598
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3453599
      Value: 35 mbar
    20. Create: Heat carrier temperature #3453600
      Value: 35 - 80 °С
    21. Create: Temperature in the DHW circuit #3453601
      Value: 35 - 60 °С
    22. Create: Hot water capacity at t 25°C #3453602
      Value: 16 l/min
    23. Create: Hot water capacity at t 30°C #3453603
      Value: 13.5 l/min
    24. Create: Max. water pressure in the DHW circuit #3453604
      Value: 6 bar
    25. Create: Max. water pressure in the heating circuit #3453605
      Value: 3 bar
    26. Create: Gas connection #3453606
      Value: 1/2"
    27. Create: Heating circuit connection #3453607
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3453608
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3453609
      Value: 60/100 mm
    30. Create: Connection of a separate chimney diameter 80 mm #3453610
      Value: Yes
    31. Create: Dimensions WxHxD #3453611
      Value: 400x727x300mm
    32. Create: Weight #3453612
      Value: 31.6 kg
    33. Create: Image #6332036
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id3764589883796596914.jpeg/orig
    34. Create: Image #6332037
      URL: https://avatars.mds.yandex.net/get-mpic/5221857/img_id8027279955600389876.jpeg/orig
    35. Create: Image #6332038
      URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id4145799055867067172.jpeg/orig
    36. Create: Preview image #6332039
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id3764589883796596914.jpeg/orig
  2. Donny Darko 30 April 2023 08:37:55
    Name: Gas boiler Baltur Tesis 28 28.2 kW double-circuit; Catalog: Heating boilers