Change history for item: Gas Thermona THERM 28 KDZ 10

  1. Donny Darko 08 July 2023 11:05:47
    1. Create: Description #3452165
      Value: Type of heating boiler: gas, max. heating power: 26.40 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3452166
      Value: Gas, condensing
    3. Create: Burner #3452167
      Value: Gas
    4. Create: Number of circuits #3452168
      Value: Double-circuit
    5. Create: Thermal power #3452169
      Value: 4.90 - 26.40 kW
    6. Create: Thermal load #3452170
      Value: 6.60 - 28 kW
    7. Create: The combustion chamber #3452171
      Value: Closed
    8. Create: Efficiency #3452172
      Value: 106 %
    9. Create: Control #3452173
      Value: Electronic
    10. Create: Installation #3452174
      Value: Wall-mounted
    11. Create: Mains voltage #3452175
      Value: Single-phase
    12. Create: Peculiarities #3452176
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: The volume of the built-in boiler #3452177
      Value: 5.5 l
    14. Create: Expansion tank volume #3452178
      Value: 7 l
    15. Create: Equipment #3452179
      Value: Built-in boiler, display
    16. Create: Fuel #3452180
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3452181
      Value: 2.85 cu. m/hour
    18. Create: LPG consumption #3452182
      Value: 0.93 kg/h
    19. Create: Nominal pressure of natural gas #3452183
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3452184
      Value: 37 mbar
    21. Create: Heat carrier temperature #3452185
      Value: 30 - 80 °С
    22. Create: Max. temperature in the DHW circuit #3452186
      Value: 60 °С
    23. Create: Hot water capacity at t 30°C #3452187
      Value: 18.6 l/min
    24. Create: Max. water pressure in the DHW circuit #3452188
      Value: 8 bar
    25. Create: Max. water pressure in the heating circuit #3452189
      Value: 3 bar
    26. Create: Gas connection #3452190
      Value: 1/2"
    27. Create: Heating circuit connection #3452191
      Value: 3/4"
    28. Create: Branch pipe for connecting the DHW circuit #3452192
      Value: 1/2"
    29. Create: Coaxial chimney diameter #3452193
      Value: 60/100 mm
    30. Create: Dimensions WxHxD #3452194
      Value: 500x1635x535mm
    31. Create: Weight #3452195
      Value: 102 kg
    32. Create: Image #6331888
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id1033527960124669647.jpeg/orig
    33. Create: Preview image #6331889
      URL: https://avatars.mds.yandex.net/get-mpic/3985831/img_id1033527960124669647.jpeg/orig
  2. Donny Darko 30 April 2023 08:37:34
    Name: Gas Thermona THERM 28 KDZ 10; Catalog: Heating boilers